11 Technical data
Installation manual
42
23EA
Daikin Altherma 3 R F
4P629088-1C – 2021.11
11
Technical data
INFORMATION
This unit is a heating only model. Therefore, all references
to cooling in this document are NOT applicable.
A
subset
of the latest technical data is available on the regional Daikin website (publicly accessible). The
full set
of latest technical data is
available on the Daikin Business Portal (authentication required).
11.1
Piping diagram: Indoor unit
3D111411
B1PW
M3S
B2PR
R3T
R8T
R2T
R1T
R5T
R4T
A
C
C
l
a2
a1
b2
b1
f
g
e
h
k
k
i
j
m
n
j
d1
c2
d2
c1
B
k
f
f
A
Water side
B1PW
Space heating water pressure sensor
B
Refrigerant side
B2PR
Refrigerant pressure sensor
C
Field installed
M3S
3-way valve (space heating/domestic hot water)
a1
Space heating water IN
R1T
Thermistor (heat exchanger – water OUT)
a2
Space heating water OUT
R2T
Thermistor (backup heater – water OUT)
b1
Domestic hot water: cold water IN
R3T
Thermistor (liquid refrigerant)
b2
Domestic hot water: hot water OUT
R4T
Thermistor (heat exchanger – water IN)
c1
Gas refrigerant IN (heating mode; condenser)
R5T, R8T
Thermistor (tank)
c2
Liquid refrigerant OUT (heating mode; condenser)
Screw connection
d1
Liquid refrigerant IN (cooling mode; evaporator)
Flare connection
d2
Gas refrigerant OUT (cooling mode; evaporator)
Quick coupling
e
Plate heat exchanger
Brazed connection
f
Shut-off valve for service (if equipped)
g
Expansion vessel
h
Magnetic filter/dirt separator
i
Safety valve
j
Air purge
k
Drain valve
l
Pump
m
Flow sensor
n
Backup heater