5 Operation

Operation manual

9

EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620243-1 – 2020.06

5.3

Possible screens: Overview

The most common screens are as follows:

+

a

OR

b

c

c2

c4

c1

c3

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

c3

: Screen with weather-dependent curve

c4

: Screen with schedule

5.3.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

26 Feb 2020

22:19

55

21
35

j

e2

l

k1
k2

k3

45

d

e1

g3

g2

g1

f

i2 i3

i4

i1

a2

a1

e3

b c

h

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

a Domestic hot water

a1

Domestic hot water

a2

55

Measured tank temperature

(a)

Item

Description

b Disinfection / Powerful

Disinfection mode active

Powerful operation mode active

c Emergency

Heat pump failure and system operates in

Emergency

 mode or heat pump is forced off.

d Current date and time

e Smart energy

e1

Smart energy is available via solar panels or smart
grid.

e2

Smart energy is currently being used for space
heating.

e3

Smart energy is currently being used for domestic
hot water.

f

Space operation mode

Cooling

Heating

g Outdoor / quiet mode

g1

6

Measured outdoor temperature

(a)

g2

Quiet mode active

g3

Outdoor unit

h Domestic hot water tank

Standalone tank installed

i

Main zone

i1

Installed room thermostat type:

Unit operation is decided based on the ambient
temperature of the dedicated Human Comfort
Interface (BRC1HHDA used as room thermostat).

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

i2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

i3

21

Measured room temperature

(a)

i4

35

Leaving water temperature setpoint

(a)

j

Holiday mode

Holiday mode active

Summary of Contents for Altherma 3 M Series

Page 1: ...Operation manual Daikin Altherma 3 M English Operation manual Daikin Altherma 3 M EBLA09 16DAV3 EBLA09 16DAW1 EBLA09 16DA3V3 EBLA09 16DA3W1 EDLA09 16DAV3 EDLA09 16DAW1 EDLA09 16DA3V3 EDLA09 16DA3W1...

Page 2: ...wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible perf...

Page 3: ...unit CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit Units are marked with the following symbol This means that electrical and electronic product...

Page 4: ...nd subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space Produce domesti...

Page 5: ...2 2 Set operation to On or Off To change the desired room temperature During room temperature control you can use the room temperature setpoint screen to read out and adjust the desired room temperat...

Page 6: ...mation see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cooling control 412 5 8 Schedule screen Example 414 5 9 Weather dependent curve 416 User reference guide 4 3 Domestic hot water To...

Page 7: ...min of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display Dials and buttons You use the dials and buttons To navigate through the...

Page 8: ...4 Quiet Activation Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule Room comfort setpoin...

Page 9: ...ive Powerful operation mode active c Emergency Heat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available vi...

Page 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Page 11: ...e home screen will be greyed out Room temperature control 1 6 bar 55 21 35 45 a 1 6 bar 55 21 35 45 b a Room temperature control ON b Room temperature control OFF Space heating cooling operation 1 6 b...

Page 12: ...pace You have to tell the system which operation mode to use To tell the system which space operation to use you can You can Location Check which space operation mode is currently used Home screen Set...

Page 13: ...the DHW tank mode is reheat the risk for capacity shortage and comfort problem is significant In case of frequent reheat operation space heating cooling function is regularly interrupted 5 7 2 Schedu...

Page 14: ...This example shows how to set a room temperature schedule in heating mode for the main zone INFORMATION The procedures to program other schedules are similar To program the schedule overview Example Y...

Page 15: ...Tue Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined...

Page 16: ...g Additional zone Cooling Tank only available to installers INFORMATION To operate weather dependent correctly configure the setpoint of the main zone additional zone or tank See 5 9 4 Using weather d...

Page 17: ...to setpoint mode Set the setpoint mode to 3 4 Additional zone Setpoint mode WD heating fixed cooling OR Weather dependent Additional zone Cooling 3 4 Additional zone Setpoint mode Weather dependent T...

Page 18: ...sary Example In the morning and evening 7 Maintenance and service 7 1 Overview Maintenance and service The installer has to perform a yearly maintenance You can find the contact helpdesk number via th...

Page 19: ...consumes extra energy See 5 7 4 Using DHW powerful operation 414 If the problems recurs daily do one of the following Increase the DHW tank temperature preset value See the user reference guide Adjust...

Page 20: ...smantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recov...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P620243 1 2020 06 Copyright 2020 Daikin 4P620243 1 0000000F Verantwortung f r Energie und Umwelt...

Reviews: