![Daikin Altherma 3 H MT ECH2O Installation Manual Download Page 26](http://html.mh-extra.com/html/daikin/altherma-3-h-mt-ech2o/altherma-3-h-mt-ech2o_installation-manual_501183026.webp)
6 Electrical installation
Installation manual
26
ETSH/X(B)12P30+50EF
Daikin Altherma 3 H MT ECH
₂
O
4P663479-1 – 2021.07
A
B
A
B
X 2M
1
2425
X
M.
12
25
X
M.
12
24
X
M.
12
25
X
M.
12
23
1
2
23
L2
L1
N
N
6
Fix the cable with cable ties to the cable tie mountings. General
information, see
"6.3.1 To connect the electrical wiring to the
15].
6.3.14
To connect the WLAN cartridge (delivered
as accessory)
[D]
Wireless gateway
1
Insert the WLAN cartridge into the cartridge slot on the user
interface of the indoor unit.
6.3.15
To connect the solar input
Wires: 0.5 mm²
Solar input contact: 5 V DC (voltage supplied by PCB)
—
1
Open the following (see
"4.2.1 To open the indoor unit"
7]):
1
User interface panel
1
3
4
2
2
Switch box
3
Switch box cover
4
Top cover
2
Connect the solar input cable as shown in the illustration below.
A
A
B
B
13 14
X 5M
1
13 14
Solar input
3
Fix the cable with cable ties to the cable tie mountings. General
information, see
"6.3.1 To connect the electrical wiring to the
6.3.16
To connect the DHW output
Wires: 2×0.75 mm²
Maximum running current: 0.3 A, 230 V AC
—
1
Open the following (see
"4.2.1 To open the indoor unit"
7]):
1
User interface panel
1
3
4
2
2
Switch box
3
Switch box cover
4
Top cover
2
Connect the DHW signal cable as shown in the illustration
below.
Summary of Contents for Altherma 3 H MT ECH2O