background image

User reference guide 

Daikin Altherma 3 H HT F

ETVZ16S18DA6V
ETVZ16S23DA6V
ETVZ16S18DA9W
ETVZ16S23DA9W

Summary of Contents for Altherma 3 H HT F

Page 1: ...User reference guide Daikin Altherma 3 H HT F ETVZ16S18DA6V ETVZ16S23DA6V ETVZ16S18DA9W ETVZ16S23DA9W...

Page 2: ...mation 30 Possible read out information 30 4 6 Space heating cooling control 31 4 6 1 About space heating cooling control 31 4 6 2 Setting the space operation mode 31 4 6 3 Determining which temperatu...

Page 3: ...a malfunction 58 7 2 To check the malfunction history 58 7 3 Symptom You are feeling too cold hot in your living room 59 7 4 Symptom The water at the tap is too cold 59 7 5 Symptom Heat pump failure 6...

Page 4: ...heater type 9 3 1 read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Backup heater Voltage 9 3 2 Configuration 9 3 3 Capacity step 1...

Page 5: ...3 H HT F 4P586461 1 2019 07 Setting Fill in Heat up mode 5 6 Comfort setpoint 5 2 Eco setpoint 5 3 Reheat setpoint 5 4 Setpoint mode 5 B WD curve type 5 E read only 1 2 Settings menu Setting Fill in...

Page 6: ...You can read out and edit more information To change the user permission level 1 Go to B User profile User profile B 2 Enter the applicable pin code for the user permission level Browse through the l...

Page 7: ...protection if enabled will remain active NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze prevention if en...

Page 8: ...ne a Actual leaving water temperature b Desired leaving water temperature To change the weather dependent curve for the space heating cooling zones 1 Go to the applicable zone Zone Go to Main zone Hea...

Page 9: ...changes b WD curve after changes c Slope d Offset Possible actions on this screen Select slope or offset Increase or decrease the slope offset When slope is selected set slope and go to offset When of...

Page 10: ...se the tank temperature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank Tank 5 2 Adjust the domestic hot water temperature 50 C 5 a b Tank a Actual domestic ho...

Page 11: ...efore changes b WD curve after changes c Slope d Offset Possible actions on this screen Select slope or offset Increase or decrease the slope offset When slope is selected set slope and go to offset W...

Page 12: ...owing symbol This means that electrical and electronic products may NOT be mixed with unsorted household waste Do NOT try to dismantle the system yourself the dismantling of the system treatment of th...

Page 13: ...tings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists...

Page 14: ...to control and monitor the status of your Daikin Altherma heat pump system For more information see http www onlinecontroller daikineurope com Breadcrumbs Breadcrumbs example 4 3 help you to locate wh...

Page 15: ...uation that could result in death or serious injury WARNING FLAMMABLE MATERIAL CAUTION Indicates a situation that could result in minor or moderate injury NOTICE Indicates a situation that could resul...

Page 16: ...onents in a typical system layout g A d b a f e c B C A Main zone Example Living room B Additional zone Example Bedroom C Technical room Example Garage a Outdoor unit heat pump b Indoor unit heat pump...

Page 17: ...g blue Standby The unit is not in operation Continuous blue Operation The unit is in operation Blinking red Malfunction A malfunction occurred See 7 1 To display the help text in case of a malfunction...

Page 18: ...your choice or go to a submenu b Back button Press to go back 1 step in the menu structure c Home button Press to go back to the home screen d Help button Press to show a help text related to the curr...

Page 19: ...frost Activation Room setpoint 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Ac...

Page 20: ...F 4P586461 1 2019 07 4 3 Possible screens Overview The most common screens are as follows a OR b c c2 c4 c1 c3 a Home screen b Main menu screen c Lower level screens c1 Setpoint screen c2 Detailed scr...

Page 21: ...e main menu Go to the main menu screen Enable disable breadcrumbs Item Description a Domestic hot water a1 Domestic hot water a2 55 Measured tank temperature a b Disinfection Powerful Disinfection mod...

Page 22: ...at installed or set Unit operation is decided based on the leaving water temperature regardless of the actual room temperature and or heating demand of the room i2 Installed heat emitter type Underflo...

Page 23: ...erma 3 H HT F 4P586461 1 2019 07 Item Description l Malfunction A malfunction occurred See 7 1 To display the help text in case of a malfunction 458 for more information a If the corresponding operati...

Page 24: ...mfort Interface BRC1HHDA used as room thermostat is controlling the indoor unit Set the room temperature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water t...

Page 25: ...ma 3 H HT F 4P586461 1 2019 07 Submenu Description A Commissioning Restriction Only for the installer Perform tests and maintenance B User profile Change the active user profile C Operation Turn heati...

Page 26: ...5 Tank temperature screen 50 C 5 Tank Explanation a1 d d e d e c a2 b1 b2 Possible actions on this screen Go through the list of the submenu Go to the submenu Adjust and automatically apply the desir...

Page 27: ...6461 1 2019 07 4 3 4 Detailed screen with values Example a b c a b c 7 2 1 Time date Hours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the...

Page 28: ...esponding temperature icon in the home screen will be greyed out Room temperature control 1 6 bar 55 19 42 18 a 1 6 bar 55 19 42 18 b a Room temperature control ON b Room temperature control OFF Space...

Page 29: ...active NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze prevention if enabled will remain active 1 Go to C...

Page 30: ...n history 8 3 Dealer information Contact helpdesk number 8 4 Sensors Room tank or domestic hot water outside and leaving water temperature if applicable 8 5 Actuators Status mode of each actuator Exam...

Page 31: ...ng 2 Check if 4 1 Operation mode is listed and editable If so a heating cooling heat pump model is installed To tell the system which space operation to use you can You can Location Check which space...

Page 32: ...tion When the unit is not in operation the status indicator will show a blue pulsation with an interval of approximately 5 seconds While the unit is in operation the status indicator will light up blu...

Page 33: ...led in by the installer To determine which temperature control you are using method 2 You can see on the home screen which temperature control you are using 6 1 6 bar 18 Feb 2018 22 19 55 18 21 45 a2...

Page 34: ...You can avoid scheduled behaviour by temporarily turning off scheduling To turn off room temperature scheduling 1 Go to 1 1 Room Schedule 2 Select No 4 6 5 To change the desired leaving water temperat...

Page 35: ...temperature The temperature will stay the same as long as there is no scheduled action The desired leaving water temperature will return to its scheduled value whenever a scheduled action occurs You...

Page 36: ...Eco action 3 hours before the scheduled start up of the disinfection function to preheat the tank When weather dependent operation is used for the tank the tank temperature is determined automatically...

Page 37: ...ture is the same as the temperature of the domestic water entering the DHW tank example 15 C At 00 00 the DHW tank is programmed to heat up the water to a preset value example Comfort 60 C During the...

Page 38: ...he setpoint screen but not modify it Instead you can modify the settings for the Comfort setpoint 5 2 Eco setpoint 5 3 and Reheat setpoint 5 4 When weather dependent operation is used for the tank the...

Page 39: ...ait for the next scheduled action to heat up the domestic hot water tank Then you can activate powerful operation The domestic hot water tank will start heating up the water to the Comfort temperature...

Page 40: ...ode is Schedule only Schedule reheat Eco setpoint Reheat setpoint If domestic hot water tank mode is Schedule reheat To define energy prices Only possible if Bivalent is enabled by the installer Prese...

Page 41: ...city supplier 3 Confirm the changes INFORMATION The values correspond with the electricity price values for High Medium and Low previously set If no schedule is set the electricity price for High is t...

Page 42: ...his example are NOT accurate Data Price kWh Gas price 4 08 Electricity price 12 49 Renewable heat incentive per kWh 5 Calculation of the gas price Gas price Actual gas price Incentive kWh 0 9 Gas pric...

Page 43: ...r temperature for the main zone in heating mode 2 3 Main zone Cooling schedule Program the desired leaving water temperature for the main zone in cooling mode 3 2 Additional zone Heating schedule Prog...

Page 44: ...stat control is active If leaving water temperature control is active you can program the main zone schedule instead 1 Go to the schedule 2 optional Clear the content of the whole week schedule or the...

Page 45: ...lect Edit Delete Edit Copy 3 Use the left dial to select an entry and edit the entry with the right dial You can program up to 6 actions each day On the bar a high temperature has a darker colour than...

Page 46: ...elect Copy Delete Edit Copy Result Next to the copied day C is displayed 3 Select Tuesday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat Wed Fri Thu...

Page 47: ...nt schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Rename Delete Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then pre...

Page 48: ...6S18 23DA6V 9W Daikin Altherma 3 H HT F 4P586461 1 2019 07 1 Program 3 room temperature schedules in heating mode and give them appropriate names Example EarlyShift DayShift and LateShift 2 Select the...

Page 49: ...ve To be able to compensate for differences in temperature the unit relies on its weather dependent curve This curve defines how much the temperature of the tank or leaving water must be at different...

Page 50: ...proceed 4 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving water...

Page 51: ...ally higher than the preferred temperature at X2 When offset is changed the new preferred temperature at X1 is equally higher as the preferred temperature at X2 c Slope d Offset e Selected weather dep...

Page 52: ...point mode WD heating fixed cooling OR Weather dependent Main zone Cooling 2 4 Main zone Setpoint mode Weather dependent Additional zone Heating 3 4 Additional zone Setpoint mode WD heating fixed cool...

Page 53: ...ther dependent curve slope offset curve The following table describes how to fine tune the weather dependent curve of a zone or tank You feel Fine tune with slope and offset At regular outdoor tempera...

Page 54: ...uiet mode is active If is displayed on the home screen quiet mode is active To program a quiet mode schedule Restriction Only possible if enabled by the installer 1 Go to 7 4 2 User settings Quiet Sch...

Page 55: ...onfigure the holiday 1 Activate the holiday mode Go to 7 3 1 User settings Holiday Activation Activation Till 7 3 1 From Select On 2 Set the first day of your holiday Go to 7 3 2 From Select a date Co...

Page 56: ...of hours For longer periods You can use the holiday mode Tips about leaving water temperature In heating mode a lower desired leaving water temperature results in lower energy consumption and better...

Page 57: ...frigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING The appliance s...

Page 58: ...f a malfunction the following will appear on the home screen depending on the severity Error Malfunction You can get a short and a long description of the malfunction as follows 1 Press the left dial...

Page 59: ...mitter type See 4 6 5 To change the desired leaving water temperature 434 The weather dependent curve is set incorrectly Adjust the weather dependent curve See 4 9 Weather dependent curve 449 7 4 Symp...

Page 60: ...s reduced and domestic hot water is NOT available auto SH normal DHW off space heating operates as normally but domestic hot water is NOT available Similarly as in Manual mode the unit can take the fu...

Page 61: ...ge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want to purge ai...

Page 62: ...ikin Altherma 3 H HT F 4P586461 1 2019 07 8 Relocation 8 1 Overview Relocation If you want to relocate parts of your system user interface indoor unit outdoor unit DHW tank contact your installer You...

Page 63: ...86461 1 2019 07 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units M...

Page 64: ...ain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application explaini...

Page 65: ......

Page 66: ......

Page 67: ......

Page 68: ...4P586461 1 2019 07 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...

Reviews: