7 Troubleshooting

Operation manual

6

ADEQ35~125C2VEB

Split system air conditioners

4P461580-1 – 2016.09

7

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  off  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause breakage, electric shock or fire. Contact your dealer.

The system must be repaired by a qualified service person:

Malfunction

Measure

If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does not properly work.

Turn off the main power
switch.

If water leaks from the unit.

Stop the operation.

The operation switch does not work
well.

Turn off the power.

If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.

Notify your installer and
report the malfunction
code.

If  the  system  does  not  properly  operate  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  according  to  the  following
procedures.

Malfunction

Measure

If the system does not
operate at all.

▪ Check  if  there  is  no  power  failure.  Wait

until  power  is  restored.  If  power  failure
occurs  during  operation,  the  system
automatically  restarts  immediately  after
the power supply is recovered.

▪ Check  if  no  fuse  has  blown  or  breaker

has worked. Change the fuse or reset the
breaker if necessary.

The system stops
immediately after
starting operation.

▪ Check  if  air  inlet  or  outlet  of  outdoor  or

indoor  unit  is  not  blocked  by  obstacles.
Remove  any  obstacle  and  make  it  well-
ventilated.

▪ Check  if  the  air  filter  is  clogged.  Contact

your dealer to clean the air filter.

Malfunction

Measure

The system operates
but cooling or heating
is insufficient.

▪ Check  if  air  inlet  or  outlet  of  outdoor  or

indoor  unit  is  not  blocked  by  obstacles.
Remove  any  obstacle  and  make  it  well-
ventilated.

▪ Check  if  the  air  filter  is  clogged.  Contact

your dealer to clean the air filter (refer to
"Maintenance" in the indoor unit manual).

▪ Check  the  temperature  setting.  Refer  to

the manual of the remote controller.

▪ Check the fan speed setting is set to low

speed. Refer to the manual of the remote
controller.

▪ Check  if  the  air  flow  angle  is  proper.

Refer  to  the  manual  of  the  remote
controller.

▪ Check  for  open  doors  or  windows.  Shut

doors and windows to prevent wind from
coming in.

▪ Check  if  direct  sunlight  enters  the  room.

Use curtains or blinds.

▪ Check if there are too many occupants in

the room during cooling operation. Check
if  the  heat  source  of  the  room  is
excessive.

▪ If  the  heat  source  of  the  room  is

excessive  (when  cooling).  Cooling  effect
decreases if heat gain of the room is too
large.

If  after  checking  all  above  items,  it  is  impossible  to  fix  the  problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).

7.1

Symptoms that are NOT system
malfunctions

The following symptoms are NOT system malfunctions:

7.1.1

Symptom: The system does not operate

▪ The  air  conditioner  does  not  start  immediately  after  the  ON/OFF

button  on  the  remote  controller  is  pressed.  If  the  operation  lamp
lights, the air conditioner is in normal condition. It does not restart
immediately because one of its safety devices actuates to prevent
the air conditioner from being overloaded. The air conditioner will
turn on again automatically after 3 minutes.

▪ The  air  conditioner  does  not  start  immediately  after  the  power

supply  is  turned  on.  Wait  1  minute  until  the  micro  computer  is
prepared for operation.

▪ The  air  conditioner  does  not  restart  immediately  when  the

temperature  setting  button  is  returned  to  its  former  position  after
pushing. It does not restart immediately because one of its safety
devices  actuates  to  prevent  the  air  conditioner  from  being
overloaded.  The  air  conditioner  will  turn  on  again  automatically
after 3 minutes.

▪ The  outdoor  unit  has  stopped.  This  is  because  the  room

temperature  has  reached  the  set  temperature.  The  unit  switches

to fan operation. "

" (external control icon) is displayed on

the remote controller and the actual operation is different from the
remote  controller  setting.  For  multi  split  models,  the  micro
computer  executes  the  following  control  depending  on  the
operation mode of other indoor units.

Summary of Contents for ADEQ35C2VEB

Page 1: ...Operation manual Split system air conditioners English Operation manual Split system air conditioners ADEQ35C2VEB ADEQ50C2VEB ADEQ60C2VEB ADEQ71C2VEB ADEQ100C2VEB ADEQ125C2VEB ...

Page 2: ...ings and symbols DANGER Indicates a situation that results in death or serious injury DANGER RISK OF ELECTROCUTION Indicates a situation that could result in electrocution DANGER RISK OF BURNING Indicates a situation that could result in burning because of extreme hot or cold temperatures DANGER RISK OF EXPLOSION Indicates a situation that could result in explosion WARNING Indicates a situation th...

Page 3: ...ire when making contact with electrical parts INFORMATION The sound pressure level is less than 70 dBA INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons WARNING Do not modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation may cause...

Page 4: ...o ensure smoother operation As soon as the power is turned on the remote controller display appears If there was a power failure during operation the system automatically restarts immediately after the power supply is recovered Set the temperature range of the remote controller is described in chapter Operation range If you select a function which is not available the message NOT AVAILABLE appears...

Page 5: ...ir filter is very dirty use a soft brush and neutral detergent 3 Dry the air filter in the shadow 4 Reattach the air filter Align the 2 hanger brackets and push the 2 clips in their place and pull the cloth if necessary rear suction bottom suction 5 Confirm that 4 hangers are fixed 6 In case of bottom suction shut the air inlet grille 7 Turn ON the power 8 Press the FILTER SIGN RESET button Result...

Page 6: ...the temperature setting Refer to the manual of the remote controller Check the fan speed setting is set to low speed Refer to the manual of the remote controller Check if the air flow angle is proper Refer to the manual of the remote controller Check for open doors or windows Shut doors and windows to prevent wind from coming in Check if direct sunlight enters the room Use curtains or blinds Check...

Page 7: ...s in cooling or defrost operation This is the sound of refrigerant gas flowing through both indoor and outdoor units A hissing sound which is heard at the start or immediately after stopping operation or defrost operation This is the noise of refrigerant caused by flow stop or flow change A squeaking sound is heard when the system is in operation or after the stop of operation Expansion and contra...

Page 8: ...4P461580 1 2016 09 Copyright 2016 Daikin ...

Reviews: