5
4. Set thermostat sub base and thermostat away from working area.
5. Using a 3/16” drill bit, drill holes in the places you have marked for mounting.
6. Use a hammer to tap supplied anchors in mounting holes.
7. Use supplied screws to mount thermostat sub base to wall (make sure thermostat wire is through hole).
8. Insert stripped, labeled wires in matching wire terminals. Tighten screws to secure wires.
CAUTION!
: Be sure exposed portion of wires do not touch other wires.
9. Gently tug wire to be sure of proper connection. Double check that each wire is connected to the proper terminal.
10. Snap thermostat onto the sub base.
11. Turn on power to the system at the main service panel.
12. Configure thermostat to match the type of system you have.
13. Test thermostat operation as described in “Testing the Thermostat”.
Terminal Designator Descriptions
A – Alarm
C – 24 VAC common
DH – Dehumidification
G – Low speed fan
G2 – High speed fan
RC, RH – 24 VAC hot
SC, S1 – Remote sensor or outdoor sensor
W1 – 1st stage heat
W2 – 2nd stage heat
W3 – 3rd stage heat
Y1 – 1st stage cool
Y2 – 2nd stage cool
Y3 – 3rd stage cool
Note 1: Not all terminals are used in every model.
Note 2: A connection to 24VAC common (C) is required.