![background image](http://html1.mh-extra.com/html/daikin/4mxs-r-series/4mxs-r-series_service-manual_4193026035.webp)
SiUS121736EA
Outdoor Unit
Specifications
22
3. Outdoor Unit
60 Hz, 208 - 230 V
Notes:
1.
Max.: for the combination of wall mounted type indoor units
Min.: for the combination of duct connected type indoor units
2.
The data are based on the conditions shown in the table below.
Model
2MXS18NMVJU
2MXS18NMVJUA
Cooling
Heating
Cooling
Heating
COP
W/W
—
4.1
—
4.1
EER
Btu/W·h
9.5 ~ 12.5
—
9.5 ~ 12.5
—
SEER / HSPF
14.0 ~ 18.9
8.2 ~ 10.7
14.0 ~ 18.9
8.2 ~ 10.7
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC36PXD
2YC36PXD
Motor Output
W
1,100
1,100
Refrigerant Oil
Model
FVC50K
FVC50K
Charge
oz (L)
21.5 (0.61)
22.0 (0.65)
Refrigerant
Type
R-410A
R-410A
Charge
Lbs (kg)
3.86 (1.75)
3.86 (1.75)
Airflow Rate
H
cfm
2,150
2,179
2,150
2,179
M
2,150
2,179
2,150
2,179
L
1,953
1,119
1,953
1,119
H
m³/min
60.9
61.7
60.9
61.7
M
60.9
61.7
60.9
61.7
L
55.3
31.7
55.3
31.7
Fan
Type
Propeller
Propeller
Motor Output
W
56
56
Running Current
A
H: 0.29 / M: 0.29 / L: 0.25
H: 0.29 / M: 0.29 / L: 0.05
H: 0.29 / M: 0.29 / L: 0.25
H: 0.29 / M: 0.29 / L: 0.05
Power Consumption
W
H: 65 / M: 65 / L: 58
H: 66 / M: 66 / L: 12
H: 65 / M: 65 / L: 58
H: 66 / M: 66 / L: 12
Starting Current
A
14.0
14.0
Dimension (H
×
W
×
D)
in. (mm)
28-15/16
×
34-1/4
×
12-5/8 (735
×
870
×
320)
28-15/16
×
34-1/4
×
12-5/8 (735
×
870
×
320)
Packaged Dimension (H
×
W
×
D)
in. (mm)
31-7/8
×
41-5/16
×
17-1/2 (810
×
1,050
×
444)
31-7/8
×
41-5/16
×
17-1/2 (810
×
1,050
×
444)
Weight (Mass)
Lbs (kg)
123 (56)
123 (56)
Gross Weight (Gross Mass)
Lbs (kg)
141 (64)
141 (64)
Sound Pressure Level
dB(A)
50
51
50
51
Piping
Connections
Liquid
in. (mm)
φ
1/4
×
2 (
φ
6.4
×
2)
φ
1/4
×
2 (
φ
6.4
×
2)
Gas
in. (mm)
φ
3/8
×
1,
φ
1/2
×
1 (
φ
9.5
×
1,
φ
12.7
×
1)
φ
3/8
×
1,
φ
1/2
×
1 (
φ
9.5
×
1,
φ
12.7
×
1)
Drain
in. (mm)
φ
11/16 (
φ
18.0)
I.D.
φ
5/8 (
φ
15.9)
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
No. of Wiring Connections
3 for Power Supply, 4 for Interunit Wiring
3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
ft (m)
164 (50) (for Total of Each Room)
164 (50) (for Total of Each Room)
82 (25) (for One Room)
82 (25) (for One Room)
Amount of Additional Charge of
Refrigerant
oz/ft
(g/m)
0.21 (20) (98-3/8 ft (30 m) or more)
0.21 (20) (98-3/8 ft (30 m) or more)
Max. Installation Height Difference
ft (m)
49-1/4 (15) (between Indoor Unit and Outdoor Unit)
49-1/4 (15) (between Indoor Unit and Outdoor Unit)
24-5/8 (7.5) (between Indoor Units)
24-5/8 (7.5) (between Indoor Units)
Drawing No.
C: 3D093257
C: 3D127128
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling
Indoor ; 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
Outdoor ; 95°FDB (35°CDB) / 75°FWB (24°CWB)
Heating
Indoor ; 70°FDB (21°CDB) / 60°FWB (15.6°CWB)
Outdoor ; 47°FDB (8.3°CDB) / 43°FWB (6°CWB)
Piping Length
25 ft (7.6 m)