![background image](http://html.mh-extra.com/html/daikin/4mxl-t-series/4mxl-t-series_service-manual_501130035.webp)
SiUS121827E
Specifications
Part 2 Specifications
29
Model
CDXS24LVJU
Cooling
Heating
Power Supply
Phase
1
φ
Hz, V
60 Hz, 208 - 230 V
Rated Capacity
24 kBtu/h Class
External Static Pressure
inH
2
O (Pa)
0.16 (40)
Airflow Rates
H
cfm
(m
3
/min)
565 (16.0)
565 (16.0)
M
523 (14.8)
523 (14.8)
L
477 (13.5)
477 (13.5)
SL
395 (11.2)
395 (11.2)
Fan
Type
Sirocco Fan
Motor Output
W
130
Speed
Steps
5 Steps, Quiet, Auto
Air Filter
Removable, Washable, Mildew Proof
Running Current (Rated)
A
0.79
0.79
Power Consumption (Rated)
W
160
160
Power Factor (Rated)
%
90.3
92.8
Temperature Control
Microcomputer Control
Dimensions (H × W × D)
in. (mm)
7-7/8 × 43-5/16 × 24-7/16 (200 × 1,100 × 620)
Packaged Dimensions (H × W × D)
in. (mm)
10-1/2 × 52-1/16 × 30-1/4 (266 × 1,323 × 768)
Weight (Mass)
Lbs (kg)
66 (30)
Gross Weight (Gross Mass)
Lbs (kg)
84 (38)
Sound Pressure
Level
H / M / L / SL
dB(A)
38 / 36 / 34 / 32
38 / 36 / 34 / 32
Heat Insulation
Both Liquid and Gas Pipes
Piping Connection Liquid
in. (mm)
φ
1/4 (
φ
6.4)
Gas
in. (mm)
φ
5/8 (
φ
15.9)
Drain
in. (mm)
VP20 (O.D.
φ
1-1/32 (
φ
26), I.D.
φ
25/32 (
φ
20))
Drawing No.
3D080590
Notes
1. SL: The quiet fan level of the airflow rate setting.
2. The operating sound is based on the rear side suction inlet and the external static pressure 0.16 inH
2
O (40 Pa).
Operating sound for bottom suction inlet : [operating sound for rear side suction inlet] +5 dB.
However, when installation resulting in lower external static pressure becomes low is carried out, the operation
sound may rise by more than 5 dB.
Model
FVXS09NVJU
FVXS12NVJU
Cooling
Heating
Cooling
Heating
Power Supply
Phase
1
φ
1
φ
Hz, V
60 Hz, 208 - 230 V
60 Hz, 208 - 230 V
Rated Capacity
9 kBtu/h Class
12 kBtu/h Class
Front Panel Color
White
White
Airflow Rates
H
cfm
(m
3
/min)
290 (8.2)
311 (8.8)
300 (8.5)
332 (9.4)
M
230 (6.5)
244 (6.9)
237 (6.7)
258 (7.3)
L
169 (4.8)
177 (5.0)
173 (4.9)
184 (5.2)
SL
145 (4.1)
155 (4.4)
159 (4.5)
166 (4.7)
Fan
Type
Turbo Fan
Turbo Fan
Motor Output
W
12.3
13.4
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable, Washable, Mildew Proof
Removable, Washable, Mildew Proof
Running Current (Rated)
A
0.14 - 0.13
0.15 - 0.14
0.14 - 0.13
0.15 - 0.14
Power Consumption (Rated)
W
15 - 15
17 - 17
15 - 15
17 - 17
Power Factor (Rated)
%
51.5 - 50.2
54.5 - 52.8
51.5 - 50.2
54.5 - 52.8
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H × W × D)
in. (mm)
23-5/8 × 27-9/16 × 8-1/4 (600 × 700 × 210)
23-5/8 × 27-9/16 × 8-1/4 (600 × 700 × 210)
Packaged Dimensions (H × W × D)
in. (mm)
27-3/8 × 30-15/16 × 11 (696 × 786 × 280)
27-3/8 × 30-15/16 × 11 (696 × 786 × 280)
Weight (Mass)
Lbs (kg)
31 (14)
31 (14)
Gross Weight (Gross Mass)
Lbs (kg)
40 (18)
40 (18)
Sound Pressure
Level
H / M / L / SL
dB(A)
38 / 32 / 26 / 23
38 / 32 / 26 / 23
39 / 33 / 27 / 24
39 / 33 / 27 / 24
Sound Power Level
dB
—
—
—
—
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection Liquid
in. (mm)
φ
1/4 (
φ
6.4)
φ
1/4 (
φ
6.4)
Gas
in. (mm)
φ
3/8 (
φ
9.5)
φ
3/8 (
φ
9.5)
Drain
in. (mm)
φ
13/16 (
φ
20)
φ
13/16 (
φ
2 0)
Drawing No.
3D101722
3D101724
Notes
1. SL: The quiet fan level of the airflow rate setting.
1. SL: The quiet fan level of the airflow rate setting.
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3