Removal of Four Way Valve / Defrost Solenoid Valve
Removal Procedure
25
6
Disconnect the 2
brazed points, first (e),
and then (f).
Remove the defrost
solenoid valve.
The defrost solenoid valve is
only for the U.S. models.
Note:
Do not use a metal saw for
cutting pipes by all means
because the sawdust comes
into the circuit.
When withdrawing the pipes,
be careful not to pinch them
firmly with pliers. The pipes
may get deformed.
Provide a protective sheet or
a steel plate so that the
brazing flame cannot
influence peripheries.
Step
Procedure
Points
(f)
(e)
(R12395)