background image

IOM 1177 / Page 3 of 8

Applications

The display sensor can be used on the products shown in 

Table 1

.

Table 1: Product usage guide

Units

 Product

Models 

Controls

Used with Digitally Adjustable Sensor 

with Temperature and Humidity Display

Water Source 

Heat Pumps

Horizontal

Enfinity

W. CCH, CCW

MicroTech III 

Unit Controller

Yes

Vertical

W. VFC, VFW

Vertical Stacked

W. VHC

Console

W. MHC, MHW

Horizontal & 

Vertical

SmartSource 1-Stage

W. GSH, GSV

MicroTech III SmartSource 

Unit Controller

SmartSource 2-Stage

W. GTH, GTV

Vertical

SmartSource Inverter

W. DFW

Daikin McQuay Inverter 

Controller

No

The display sensor for water source heat pump applications is shown in 

Table 2

Table 2: Water source heat pump application guide

Units

Product

Models

Applications

Cool-

ing

Heat-

ing

Dehumidification

Electric Heat

Water-

side 

Econo-

mizer

Stages

Smart 

Dehu-

midifi

-

cation

Hot Gas 

Reheat

Simpli-

fied

Hu-

midistat 

Con-

trolled

Dehu-

midifi

-

cation 

Only

Boil-

erless

Supple-

mental

Primary

3-Way 

Valve 

Control

Water 

Source 

Heat 

Pumps

Hori-

zontal 

Enfinity

W. CCH, 

CCW

1

1

No

No

No

No

No

No

No

No

No

Vertical

W. VFC, 

VFW

1

1

No

Yes

No

No

No

Yes

1

Yes

No

No

Vertical 

Stacked

W. VHC

1

1

No

No

No

No

No

No

No

No

No

Console

W. MHC, 

MHW

1

1

No

No

No

No

No

Yes

1

Yes

No

No

Hori-

zontal & 

Vertical

Smart-

Source 

1-Stage

W. GSH, 

GSV

3

4

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Hori-

zontal & 

Vertical

Smart-

Source 

2-Stage

W. GTH, 

GTV

3

4

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Vertical

Smart-

Source 

Inverter

W. DFW

NA

NA

No

No

No

No

No

No

No

No

No

Note: 

1

With optional Boilerless controls

Termination

Daikin McQuay recommends using twisted pair of at least 

22AWG and sealant filled connectors for all wire connec

-

tions. Larger gauge wire may be required for long runs. All 
wiring must comply with the National Electric Code (NEC) 
and local codes. Do NOT run this device’s wiring in the same 

conduit as AC power wiring. Fluctuating and inaccurate 
signal levels are possible when AC power wiring is present in 
the same conduit as the signal lines. If you are experiencing 

any of these difficulties, please contact your Daikin McQuay 

representative.

Summary of Contents for IOM 1177

Page 1: ...cquay com Room Temperature Sensor Adjustable Cool Warm With Occupancy Switch Sensor Part No 910121753 Used With Water Source Heat Pumps SmartSource Units with MicroTech III Controls Models GS GT Enfinity Units with MicroTech III Controls Models CCH CCW VFC VFW LVC LVW MHC MHW VHC VHF IMPORTANT Operator save these instructions for future use ...

Page 2: ...nd should be handled carefully Rough handling or distorting components could cause the control to malfunction The remote sensors cannot be used with systems where power interruptions are part of normal system operation NOTICE MERCURY NOTICE This product does not contain mercury However this product may replace a product that contains mercury Mercury and products containing mercury must not be disc...

Page 3: ...Supple mental Primary 3 Way Valve Control Water Source Heat Pumps Hori zontal Enfinity W CCH CCW 1 1 No No No No No No No No No Vertical W VFC VFW 1 1 No Yes No No No Yes1 Yes No No Vertical Stacked W VHC 1 1 No No No No No No No No No Console W MHC MHW 1 1 No No No No No Yes1 Yes No No Hori zontal Vertical Smart Source 1 Stage W GSH GSV 3 4 Yes Yes Yes Yes Yes Yes Yes Yes Yes Hori zontal Vertical...

Page 4: ...apping the bottom into position Figure 1 Junction box mounting Junction box Field provided thermostat wiring 6 32 1 2 mountings screws Drywall Mounting 1 Place the base plate against the wall where you want to mount the sensor 2 Mark out the two mounting holes where the unit will be attached to the wall Drill a 3 16 hole in the center of each mounting hole and insert a drywall anchor into the hole...

Page 5: ...t Fan Unit Mode Setpoint Adjustment Room Temperature Sensor Tenant Override DC Signal Common Emergency Shutdown Unoccupied Adjustable Cool Warm Room Temperature Sensor with Occupancy Switch Part No 910121753 Maintenance Wipe the display as needed with a damp water only cotton cloth Do not use any type of cleaner as it may damage the buttons or scratch the display Do not paint Terminal Descriptions...

Page 6: ...ycle on a call for heat or cool in the unoccupied mode Status LED This green LED will light to indicate the system status See Table 8 for unit status LED definitions Override Button When the Override button is pressed the thermistor sensor across terminal 4 is shorted If held for more than 5 seconds but less than 11 seconds it puts the water source heat pump controller into a timed Occupied Overri...

Page 7: ...IOM 1177 Page 7 of 8 This page left blank intentionally ...