background image

Q-222-032 

 

10 

 

7.5 EMC 

 

Item 

Specification 

Electrostatic 
discharge immunity 
test 

Contact discharge 
  ±4kV (Charge voltage) 
Air discharge 
  ±8kV (Charge voltage) 

Performance 
standard:B 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-2 

Radiated, 
radio-frequency, 
electromagnetic  
field immunity test 

Frequency:① 80 to 1000MHz 

Performance 
standard:A 

During testing: 

Within ±20% error 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-3 

② 1.4 to 2.0GHz  
③ 2.0 to 2.7GHz 

Field strength:① 10V/m  

② 3V/m  
③ 1V/m 

Amplitude modulation:80%AM (1kHz) 

Electrical fast 
transient / burst 
immunity test 

Power port 
(DC) 

±2.0kV 

Performance 
standard:B 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-4 

Power port 
(AC) 

±2.0kV 

Signal port  ±1.0kV 

Surge immunity test 

Power port 
(DC) 

Line to ground ±0.5kV 
Line to line   ±0.5kV 

Performance 
standard:B 

After test:Within 
inherent error 

EN61000-6-2 
EN61000-4-5 

Power port 
(AC) 

Line to ground ±2.0kV 
Line to line   ±1.0kV 

Signal port  Line to ground ±1.0kV 

Immunity to conducted 
disturbances, induced 
by radio frequency 
fields 

Frequency:0.15 to 80MHz 
Voltage level:10V, 80%AM (1kHz) 

Performance 
standard:A 

During testing: 

Within ±20% error 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-6 

Power frequency 
magnetic field 
immunity test 

Frequency:50/60Hz 
Field strength:30A/m 

Performance 
standard:A 

During testing: 

Within ±20% error 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-8 

Voltage dips, short 
interruptions and 
voltage variations 
immunity tests (AC 
power supply port) 

Residual voltage:0%, 1 cycle 

Performance 
standard:B 

After test:Within 
 inherent error 

EN61000-6-2 
EN61000-4-11 

Residual voltage:40%, 10/12 cycle 

Performance 
standard:C 

After test:Within 
 inherent error 

Residual voltage:70%, 25/30 cycle 
Residual voltage:0%, 250/300 cycle 

Electromagnetic 
radiation disturbance 

Frequency band 30 to 230MHz, 10m distance:40dB (μV/m) or less 
Frequency band 230 to 1000MHz, 10m distance:47dB (μV/m) or less 

EN61000-6-4 
EN55011 
classA, Group1 

Terminal interference 
voltage 

Power port (AC): 

Frequency band 0.15 to 0.5MHz, Quasi-peak:79dB or less,  

Average   :66dB or less 

Frequency band 0.5 to 30MHz,   Quasi-peak:73dB or less, 

Average   :60dB or less 

Performance standard A:During and after the test the equipment shall be able to continue operation as  

specified. 

Performance standard B:The equipment shall be able to continue operation as specified after the test. 

However, performance degradation during testing is allowed. 

Performance standard C:Temporary loss of function is allowed, but the function can be self-healing or  

can be recovered by operation of the control device. 

 

Summary of Contents for FSPTT2-92A-33

Page 1: ...Q 222 032 INSTRUCTION MANUAL POWER FLOW THREE PHASE POWER FACTOR TRANSDUCER FSPTT2 92A 33...

Page 2: ...ase do not install in the place where sunlight hits directly Discoloration and degradation of a name plate and deformation of the case by the surface temperature rise may occur If the average daily te...

Page 3: ...our company Failure caused by violating various conditions regarding use storage etc specified by the supplier When the faults or defects are caused by a reason not belongs to purchased or delivered p...

Page 4: ...thod 4 5 Connection 6 6 Handling explanation 7 7 Specification 7 1 Rating 7 7 2 Performance 8 7 3 Electrical strength Mechanical strength 9 7 4 Noise immunity 9 7 5 EMC 10 7 6 Structure and environmen...

Page 5: ...with a width of 35mm The terminal cover is standard equipment 3 Bundled items Inspection certificate 1 Packed in an envelope Terminal screw in a bag M4 screw 4 piece set 1 M4 screw 7 piece set 1 4 Mo...

Page 6: ...this product from the IEC DIN rail Please insert a flathead screwdriver in the hole where a slider is square Next a slider is lowered in the direction of an arrow This product can be removed from the...

Page 7: ...g torque 1 0 to 1 3 N m Connection diagram 3 1 2 S1 AUX SUPPLY P1 1L 1S 3S S2 P2 OUTPUT A B 3L E LOAD Grounding is class D grounding grounding resistance 100 or less If there is a power line that caus...

Page 8: ...ed current Indefinite 6 The output value when only the auxiliary power supply is applied or when the auxiliary power supply and voltage input are applied is the output equivalent to the power factor 1...

Page 9: ...tment range is BIAS 5 of the output span MAX 5 of the output span Use only when adjustment is required for matching with connected devices Low input cut Output equivalent to the power factor 1 for pow...

Page 10: ...ond of rated voltage 10 times 10 second intervals 40 times 1 second and 20 times 4 seconds and 10 times 16 seconds of rated current 2 times 1 minute intervals 10 times 1 second of rated current 5 time...

Page 11: ...61000 4 6 Power frequency magnetic field immunity test Frequency 50 60Hz Field strength 30A m Performance standard A During testing Within 20 error After test Within inherent error EN61000 6 2 EN61000...

Page 12: ...its 10 to 55 5 to 90 RH Non condensing Storage temperature limits 40 to 70 Product warranty period One year period 7 7 Technical standards Item Specification Transducer JIS C 1111 2019 IEC 60688 2012...

Page 13: ...0 5 1 0 5 0 LEAD LAG LEAD LAG INPUT Power transmission Power receiving V mA 3 12 OUTPUT 5 20 1 4 4 16 2 8 0 0 5 1 0 5 0 0 5 1 0 5 0 LEAD LAG LEAD LAG INPUT Power transmission Power receiving V mA 2 5...

Page 14: ...cated on the name plate or a simulated load with the same resistance value as the actual load 2 Apply the auxiliary power supply rated and the input equivalent to 50 of the rated output value and ener...

Page 15: ...ving DC0 to 2 5 to 5V 3 DC20 to 57V 4 Power transmission DC0 to 5 to 10V 2k or more Z Other Power receiving DC0 to 5 to 10V 5 Power transmission DC1 to 3 to 5V 600 or more Power receiving DC1 to 3 to...

Page 16: ...receiving DC3 to 4 to 5V 6 Power transmission DC 5 to 2 5 to 0V 600 or more Power receiving DC0 to 2 5 to 5V 7 Power transmission DC 10 to 5 to 0V 2k or more Power receiving DC0 to 5 to 10V A Power tr...