43
-
10. OPERATION
(Continued)
10.2 Applied setting
10.2.1 Setting of Internal Function
The welding power supply various built-in internal functions, as shown in the following table.
This welding power source has all kinds of special internal functions which can be set through
DISPLAY CHANGE key [7].
●
Usage of Internal Function
(1) Push and hold down DISPLAY CHANGE key[7] for a few seconds to switch to the internal
function mode. The left digital meter will display a function number, and the right digital
meter will light up to display the function status corresponding to the function number.
(2) Adjustment of function number and status.
No. Internal Function
No.
Internal Function
F1
Fine adjustment of
anti-stick(burnback) time
F11
Fine adjustment of JOB
MEMORY
F2
Fine adjustment of anti-stick(burnback)
Voltage
F12
Setting of soft arc mode
F3
Fine Adjustment of Slow Down Speed
F13
Penetration Control function
F4
Switch of Auto/Semi-automatic Mode
F14
Switch of Wire feeding
machine selection
F5
Switch of external setting voltage
range
F15
Setting of INITIAL Condition
F6
Setting of up-slope time
F16
Gas Pre-flow time
F7
Setting of down-slope time
F17
Gas Post-flow time
F8
Setting of result display time
F18
-
F9 -
F19 -
F10 Disabling Power Saving Function
F20
-
This example shows
function number “F5”
with its “on” status.
This example
shows function
number “F11” with
its “OFF” status.
Function Status
Change function status by
VOLTAGE adjusting knob [5].
Function Number
Change function number by
CURRENT adjusting knob [4].
Wminfo