background image

11

3P130768-6L   English

<Combined operation system with VRV system (connected with Heat Reclaim Ventilator units and standard indoor units in a single refrigerant circuit)>

<Independent system (connected only with a Heat Reclaim Ventilator unit in a single refrigerant circuit)>

<When including a BS unit>

F1 F2 F1 F2

R

S

P1 P2 F1 F2 T1 T2

R

S

P1 P2 F1 F2 T1 T2

L N

P1 P2 F1 F2 T1 T2

Tr

a

n

s

mi

ss

ion wiring

O

u

tdoor 

u

nit

F

us

e

S

witch

Remote controller

Remote controller wiring

IN/D

OUT/D

Control 

b

ox

S

t

a

nd

a

rd indoor 

u

nit A

E

a

rth

E

a

rth

E

a

rth

Remote controller

S

t

a

nd

a

rd indoor 

u

nit B

He

a

t Recl

a

im 

Ventil

a

tor A 

(O

u

t

s

ide 

a

ir 

proce

ss

ing type)

Power 

su

pply

220-240V

~

50 Hz

F

us

e

S

witch

Power supply

220-240V

~    

50 Hz

F

us

e

S

witch

Power 

su

pply

220-240V

~

50 Hz

F1 F2 F1 F2

R

S

P1 P2 F1 F2 T1 T2

Tr

a

n

s

mi

ss

ion wiring

O

u

tdoor 

u

nit

IN/D

OUT/D

Control 

b

ox

S

t

a

nd

a

rd indoor 

u

nit A

S

t

a

nd

a

rd indoor 

u

nit B

E

a

rth

E

a

rth

E

a

rth

Remote controller

Remote controller

Remote controller

He

a

t Recl

a

im 

Ventil

a

tor A

(O

u

t

s

ide 

a

ir 

proce

ss

ing or 

s

t

a

nd

a

rd type)

NOTE)

R

S

P1 P2 F1 F2 T1 T2

L N P1 P2 F1 F2 T1 T2

NOTE) 

S

t

a

nd

a

rd type ........ VAM 

s

erie

s

F

us

e

S

witch

Power 

su

pply

220-240V

~

50 Hz

F

us

e

S

witch

Power 

su

pply

220-240V

~

50 Hz

F

us

e

S

witch

Power 

su

pply

220-240V

~    

50 Hz

R

S

P1 P2 F1 F2 T1 T2

L N P1 P2 F1 F2 T1 T2

Tr

a

n

s

mi

ss

ion wiring (No pol

a

rity)

Remote controller
wiring

O

u

tdoor 

u

nit

Power 

su

pply

220-240V

~

50 Hz

Power 

su

pply

220-240V

~

50 Hz

B

S

 

u

nit

E

a

rth

E

a

rth

Remote 
controller

F1 F2 F1 F2

F1 F2 F1 F2

IN/D

OUT/D

OUT/D

IN/D

Control 

b

ox

Control 

b

ox

S

t

a

nd

a

rd indoor 

u

nit A

He

a

t Recl

a

im Ventil

a

tor A 

F

us

e

S

witch

F

us

e

S

witch

01_EN_3P130768-6L.fm  11 ページ  2013年3月21日 木曜日 午前11時48分

Summary of Contents for VKM100GBMV1

Page 1: ...puchons de formes arrondies des grilles d aspiration vacuation d air avant l installation de cette unit Ventilaci n con recuperaci n de calor Por favor lea cuidadosamente el manual de instalacion e in...

Page 2: ...icable for a certain product or domain Be sure to use only the specified parts and accessories for installation work Failure to use the specified parts may result in the Heat Reclaim Ventilator unit f...

Page 3: ...ntil installation work is done 1 Decide upon a line of transport 2 Leave the unit inside its packaging while moving until reach ing the installation site Where unpacking is unavoidable use a sling of...

Page 4: ...be sufficient enough to eliminate the electric noise The bellows may not be able to be used in some districts so exercise caution Contact your local government office or fire department for details Wh...

Page 5: ...aring the weight of the unit Refer to Fig 3 5 THE METHOD OF INSTALLATION CAUTION Hold underside of the unit or hanger bracket without putting force on other parts when unpacking or moving the unit As...

Page 6: ...greater than or equal to the diameter of the connecting pipe pipe size PT3 4B When piping passes indoors always insulate it all the way to the base of the drain socket In areas where freezing may occu...

Page 7: ...ing that passes indoors After checking that the water supply piping connections do no leak insulate them using the included insulation as shown in Fig 10 Tighten both edges with clamping material Refe...

Page 8: ...e connections Refer to Fig 14 CAUTION When brazing a pipe while feeding nitrogen inside the pipe make sure to set the nitrogen pressure to 0 02 MPa 0 2 kg cm 2 or less using the pressure reducing valv...

Page 9: ...g and insects tends to swarm around the light minute insects may intrude indoors through the air supply opening and air filter In such cases the use of a high performance filter sold sep arately is re...

Page 10: ...wiring through holes to prevent damage to them Make sure the remote controller wiring the wiring between the units and other electrical wiring do not pass through the same locations outside of the uni...

Page 11: ...iring their respective terminal blocks 10 4 WIRING FOR THE HUMIDITY REGULATOR LOCALLY PROCURED VKM GBMV1 SERIES ONLY Pass into the control box together with the power wire through the power wiring thr...

Page 12: ...Fuse Switch Power supply 220 240V 50 Hz F1 F2 F1 F2 R S P1 P2 F1 F2 T1 T2 Transmission wiring Outdoor unit IN D OUT D Control box Standard indoor unit A Standard indoor unit B Earth Earth Earth Remote...

Page 13: ...ONTROL FORCED OFF AND ON OFF OPERATION Wire specifications and how to perform wiring Connect the input from outside to terminals T1 and T2 of the terminal block for remote controller The equipment in...

Page 14: ...AL button for more than four seconds with the unit in the normal mode to enter the local setting mode 2 Use the TEMPERATURE ADJUSTMENT button to select the desired MODE NO The code display will blink...

Page 15: ...n 17 27 0 Approx 2500 hours Approx 1250 hours No counting Nighttime free cooling operation ON OFF and starting time 1 OFF ON 2hours later ON 4hours later ON 6hours later ON 8hours later Initial settin...

Page 16: ...ting Heating humidification 21 C Cooling suction temperature at refrigerant heat exchanger 26 C Configurable range of set temperature Heating humidification 14 to 26 C Cooling 18 to 33 C The correlati...

Page 17: ...listening for that clicking sound let the unit run for 30 minutes to make sure that humidifying operation is normal CAUTION If carpentry work is not completed when a test run is fin ished tell the cu...

Page 18: ...white page fm 1...

Page 19: ...white page fm 2...

Page 20: ...EM12A038 1303 3P130768 6L DE 00_CV_3P130768 6L fm 2...

Reviews: