4.1.1.2  A&C Manager 

 

Figure 4- 2 

 

Parameter 

Note 

Unlock 

Responding 

Interval 

The  interval  between  current  unlock  and  next  one, 

unit is second.   

Unlock Period 

Period door remains unlocked, unit is second. 

Door  Sensor  Check 

Time 

When  only  use 

door  sensor,  check”Check  Door 

Sensor Signal Before Lock”, Set “Door Sensor Check 
Time” to enable it.   
When  door  remains  unlocked  over  set  door  sensor 

check time, it alarms.   

Check  Door  Sensor 

Signal Before Lock 

 

4.1.1.3  System Time 

Here you can set date format, time format, and input system date and time. You can also 

click on Sync PC to synchronize system time with PC time.   

 

4.1.2 LAN Config 

Here you can register VTO to center and set how to call center. Please refer to Ch 5.1.1. 

 

4.1.3 Indoor Manager 

In Indoor Manager interface, you can add VTH (digital indoor station), view VTH info and 

delete VTH.   

 

Figure 4- 3 

 

Summary of Contents for VTO2000A-2

Page 1: ...i 2 Wire VTO2000A 2 User s Manual V1 0 0...

Page 2: ...One Scene 3 1 3 2 Group Call Scene 4 2 Install VTO 5 2 1 Direct Installation 5 2 1 1 Screw 5 2 1 2 Dimension 5 2 1 3 Installation Step 6 2 2 Embedded in Wall 8 2 2 1 Screw 8 2 2 2 Dimension 8 2 2 3 In...

Page 3: ...Status Statistics 22 4 3 1 VTH Status 22 4 4 Logout 22 5 Basic Function Introduction 23 5 1 Call Function 23 5 1 1 Call Manager Center 23 5 1 2 Call User 24 5 1 3 Group Call 24 5 2 Monitor 26 5 3 Unlo...

Page 4: ...iii Appendix 2 3 Embedded Box 30...

Page 5: ...all off or turnover Do not place the device on carpet or quilt Do not block air vent of the device or ventilation around the device Otherwise temperature in device will rise and may cause fire Do not...

Page 6: ...via IC card Button Type Lock Control Module VTO2000A 2 Metal Silver N A Mechanical key Built in 1 2Structure 1 2 1Dimension Before you install the device please make sure you know the dimension of de...

Page 7: ...corresponding door region 3 Compensation Light Light compensation will automatically turn on during monitoring calling or connecting status if there is no enough light in environment 4 Speaker Audio o...

Page 8: ...center 3 User Port Connect to lock door sensor feedback and unlock button 4 Project Port Reserved for project staff use 1 3System Networking This chapter mainly introduces usage of digital VTO please...

Page 9: ...Call Scene When visitor press Call button on VTO multiple VTHs will ring at the same time User can call hang up and unlock on any of these VTHs Note VTH has 1 master VTH and up to 3 extension VTHs Se...

Page 10: ...s guide Component Name Illustration Quantity M3 6 Hex slot pan head tail machine screws galvanizing white 4 ST3 18 Cross recessed countersunk head tail tapping screws galvanizing white 4 White expansi...

Page 11: ...18 Cross recessed countersunk head tail tapping screws galvanizing white and fix metal bracket on wall See Figure 2 2 Step 2 Align the device on metal bracket according to screw hole Fasten screw M3...

Page 12: ...7 Figure 2 2...

Page 13: ...following specifications and install by following this guide Component Illustration Quantity M3 6 Hex slot pan head tail machine screws galvanizing white 4 Chart 2 2 2 2 2Dimension Before you install...

Page 14: ...e Figure 2 5 Step 2 Embed metal bracket into wall until its four peaks lean against the wall See Figure 2 6 Step 3 Align the device on metal bracket according to screw hole Fasten screws M3 6 Hex slot...

Page 15: ...10 Figure 2 5 Figure 2 6...

Page 16: ...11 Figure 2 7 2 3Wiring See Figure 2 8 Figure 2 8 No Component Name Note 1 User Port 2 wire Power supply no...

Page 17: ...VTO connects to electric control lock it means that the positive end of electronic control lock connects to NO of VTO user port 10 while its negative end connects to COM of VTO user port 12 When VTO...

Page 18: ...hile its negative end connects to COM of VTO user port 12 When VTO connects to door sensor in electromagnetic lock one end of door sensor connects to FEEDBACK of VTO user port 8 while the other end co...

Page 19: ...If you first use VTO you may need to operate according to the following steps Step 1 First make sure your PC and the VTO are well connected and follow steps below to login WEB interface Step 2 In Int...

Page 20: ...192 168 1 110 Default username and password is admin admin After first login please change your password Step 2 In WEB interface select System Config Local Config set video format as WVGA as in Figure...

Page 21: ...Parameter Note Video Format Set video format that collected by the camera including WVGA and D1 WVGA resolution is 800 480 D1 resolution is 704 576 Device Type Display device type Frame Rate NTSC 30 f...

Page 22: ...me to enable it When door remains unlocked over set door sensor check time it alarms Check Door Sensor Signal Before Lock 4 1 1 3 System Time Here you can set date format time format and input system...

Page 23: ...address Note VTH short no consists of four digits the first two digits can be within 01 99 the last two digits can be within 01 16 Note Parameters with are mandatory 4 1 4Network Config Here you can...

Page 24: ...ideo Set interface See Figure 4 6 Figure 4 6 Parameter Note Gain Gain limit of video basic parameter Scene Mode Select mode automatic sunny night and etc Day Night Mode Color mode Back Light Mode Back...

Page 25: ...web 4 1 6User Manage Only when you login as admin you can add modify delete and view user info in User Manage interface Add User In User Manage interface click on Add User system pops up Figure 4 7 Fi...

Page 26: ...te user 4 2Info Search 4 2 1Call History Here you can view call history of VTO in Call History interface It can save up to 1024 items Figure 4 9 4 2 2Alarm Record You can search VTO alarm record on Al...

Page 27: ...H are not connected you cannot call monitor talk or etc Online VTO and VTH are connected you can call monitor talk and etc MON Unmon VTH is not monitoring Onmom VTH is monitoring See Figure 4 11 Figur...

Page 28: ...a visual bidirectional talk with the manager center You can touch the button on VTO to end call at any time Step 1 According to VTO configured for the center fill in building no building unit no and V...

Page 29: ...on on VTO to call multiple VTH at the same time VTH consists of master VTH and extension VTH A system can only have a max of 1 master VTH and 5 extension VTHs Please refer to VTO2000A Series Installat...

Page 30: ...e 5 2 Note Paramete with are mandantory to be set Step 4 In LAN Config interface check Group Call and click on OK See Figure 5 3 Step 5 After config is complete enter Logout interface to reboot VTO Fi...

Page 31: ...called calling or monitoring VTH can remotely unlock door VTO will return to standby interface after call ends or countdown stops 5 4Compensation of Light In dark environment or at night the VTO adop...

Page 32: ...ed you can restore VTH info with this function Note Every half hour VTO automatically saves card and VTH info in the system If you want to restore card and or VTH info you must restore within half hou...

Page 33: ...ress button on VTO and there will be sound from the device 3 Q The device could not boot up and there was no sound or light A Please check if power supply is well plugged 4 Q My call did not go though...

Page 34: ...ight Vision Support Audio Input Omnidirectional Mic Output Built in speaker Talk Support bidirectional talk Operation Mode Input Single key input Door Lock Status Check Support optional Network Ethern...

Page 35: ...nal Note Please do not let LN be over 100m Appendix 2 2 Power Extension Line Specification The wiring length between VTO and adaptor is LC so reasonable specification of extnsion line is Extension Lin...

Page 36: ...re here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refe...