Dahua SD22 Series Installation Manual Download Page 7

 

 

1

 

Installation Preparation 

1.1

 

Basic Requirements 

 

All installation and operation here should conform to your local electrical safety codes, fire 

protection regulations and relevant regulations. 

 

Make sure if the application scenarios of speed dome conforms to the installation 

requirements. Please contact your local retailer if you have any confusion. 

 

Please use the product according to the operating environment. 

 

Please keep the original packing material well after opening the package, which is used to 

pack speed dome and send it back for repair in case problems happen. 

1.2

 

Installation Check 

 

Please make sure the installation environment has enough space to install the speed dome 

and its corresponding mounting components.  

 

Please make sure the ceiling and wall can sustain 8X weight of the speed dome and its 

mounting components. 

 

Please make sure the wall is thick enough to install expansion bolts (Users need to 

purchase expansion bolts separately). 

 

It needs to guarantee that the mounting height has to be more than 6m if the speed dome is 

laser speed dome. 

1.3

 

Cable Preparation 

Please select video cable and lowest specification requirement of video coaxial cable according 

to the transmission distance. 

1.3.1  Cable Lowest Specification Requirement 

 

75 ohm impedance. 

 

Full cable with copper conductor. 

 

95% knitted copper shield.

 

International Model 

Max Transmission Distance 
(Ft\M) 

RG59/U 

750Ft/229M 

RG6/U 

1,000Ft/305M 

RG11/U 

1,500Ft/457M 

Note 

The above can be applied to analog speed dome and network speed dome. 

International Model

 

Max Transmission Distance 

(M\Ft)

 

SYV-75-3 

720P(25fps\30fps)

500M/1640Ft 

720P(50fps\60fps)

300M/984Ft 

1080P(25fps\30fps): 300M/984Ft 

Note 

The above can be applied to HDCVI speed dome.  

1.3.2  Select Needed Power Supply Cable According to Transmission Distance 

Refer to appendix 

Ⅱ 

for DC 12V power supply device. 

 

Summary of Contents for SD22 Series

Page 1: ...2 inch Network Speed Dome Installation Manual Version 1 0 2 ...

Page 2: ...TALLATION 2 2 1 Check Accessories 2 2 2 Open Device 2 2 3 Installation Position Map 2 2 4 SD Card Slot and Rest Button 3 3 CAMERA INSTALLATION 4 3 1 Component Installation 4 3 2 Installation Steps 5 3 2 1 Installation Conditions 5 3 2 2 Installation Steps 5 4 APPENDIX Ⅰ LIGHTENING PROTECTION AND SURGE PROTECTION 6 4 1 Outdoors 6 4 2 Indoors 7 5 APPENDIX Ⅱ DC 12V WIRE GAUGE AND TRANSMISSION DISTANC...

Page 3: ...ii Welcome Thank you for purchasing our speed dome Please read the following safeguards and warnings carefully before you install or use the product ...

Page 4: ... is an optional risk of death or series injury Note It is to alert you there is an optional risk of damage or property loss Warning 1 All installation and operation here should conform to your local electrical safety codes We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation 2 Be sure to use all the accessories such as power ada...

Page 5: ...nal injury or device damage resulting from opening the shell Please contact your local retailer if there is internal setup or maintenance requirement We are not liable for any problems caused by unauthorized modifications or attempted repair 4 Do not allow other object falling into the device Please make sure there is no metal or inflammable explosive substance in the speed dome The above mentione...

Page 6: ...id to clean the shell and then use soft cloth to make it dry Do not use gasoline dope thinner or other chemical material to clean the shell It may result in shell transfiguration or paint flake Do not allow the plastic or rubber material to touch the shell for a long time It may result in paint flake ...

Page 7: ...unting components Please make sure the wall is thick enough to install expansion bolts Users need to purchase expansion bolts separately It needs to guarantee that the mounting height has to be more than 6m if the speed dome is laser speed dome 1 3 Cable Preparation Please select video cable and lowest specification requirement of video coaxial cable according to the transmission distance 1 3 1 Ca...

Page 8: ... all the components listed are included Please check the container list for details 2 2 Open Device Remove the package and then take out the device See Figure 2 1 Figure 2 1 2 3 Installation Position Map The installation position map is used for drilling positioning on the hard ceiling and cable exit position Refer to Figure 2 2 for more details Figure 2 2 ...

Page 9: ...make sure the SD card is in the non read write state when removing it Otherwise it may result in data loss and SD card damage The button is used for default setting Long press Reset button for more than 5 seconds the system configuration information will be recovered to default setting Figure 2 3 ...

Page 10: ...e mainly adopts ceiling mount mode which can be installed on the ceiling or wall 3 1 Component Installation The speed dome and its mounting component are shown in Figure 3 1 Figure 3 1 The ceiling mounted speed dome is shown in Figure 3 2 Figure 3 2 ...

Page 11: ... the method shown in Figure 3 1 Step 2 Confirm installation position and wiring mode first mark punching position and dig holes on the ceiling according to the installation position map and then insert three plastic expansion bolts into the holes you just dug Step 3 Use inner hex wrench to loosen three locking screws on the enclosure and then remove the enclosure Step 4 Lay the outgoing line well ...

Page 12: ...ects one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and confo...

Page 13: ...ND wire or GND screw of the speed dome should be reliably connected by several strands of copper wire with no less than 25mm and indoor equipotential GND terminal Please refer to Figure 4 2 for lightningproof installation mode Figure 4 2 ...

Page 14: ... 22 72 190 83 58 16 25 24 43 7 45 38 17 11 63 59 63 18 18 152 66 46 53 30 20 35 6 20 31 80 9 69 49 69 15 15 127 22 38 78 35 17 45 5 32 27 26 8 31 42 60 12 98 109 04 33 24 40 15 27 4 65 23 85 7 27 37 27 11 36 95 41 29 08 45 13 57 4 14 21 20 6 46 33 13 10 10 84 81 28 85 50 12 21 3 72 19 08 5 82 29 82 9 09 76 33 23 27 55 11 10 3 38 17 35 5 29 27 11 8 26 69 39 21 15 60 10 18 3 10 15 90 4 85 24 85 7 57...

Page 15: ... 00950 0 130 36 39 0 01327 0 140 35 0 01539 0 160 34 37 0 02011 0 180 33 0 02545 0 200 32 35 0 03142 0 230 31 0 04115 0 250 30 33 0 04909 0 290 29 31 0 06605 0 330 28 30 0 08553 0 350 27 29 0 09621 0 400 26 28 0 1257 0 450 25 0 1602 0 560 24 24 0 2463 0 600 23 23 0 2827 0 710 22 22 0 3958 0 750 21 0 4417 0 800 20 21 0 5027 0 900 19 20 0 6362 1 000 18 19 0 7854 1 250 16 18 1 2266 1 500 15 1 7663 2 ...

Page 16: ...tware here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website or contact your local service engineer for more information ...

Reviews: