14
Figure 2-7
c). Lens tilt rotation angle. Please refer to Figure 2-8 to unfasten the lock screw B and lock screw C
and adjust the tilt monitor angle to the proper position. Then fix the lock screw B and lock screw C. The
tilt angle ranges from -23°~+73°.
d). Image pan rotation angle setup. Please refer to Figure 2-8 to turn lock screw D to adjust the video
pan angle. Then fix the lock screw B and C. The video pan angle ranges from 0°~+350°.
Figure 2-8
e) For the motorized zoom series product, please skip current step. Please refer to chapter 2.2.2 for
the lens zoom and focus operation of the manual focus series product.
f) For the IR series product, please skip current step and complete the angle setup directly. For the
non-IR series product, please put back the black plastic decoration enclosure to complete the angle
setup.
Important
Please note Figure 2-7 and Figure 2-8 is based on the IR motorized zoom camera. For the IR
manual zoom camera and non-IR series product, the lock screw position and the lens angle
adjustment are the same.
Step 7
Line up the dome camera protection enclosure to the cable exit on the side panel. Put the enclosure
back and then use the inner hex wrench to secure the 3 inner hex screws firmly. Now the installation is
complete.
Note
Usually we recommend, after the installation, please take the three white static protection gaskets from
the accessories bag and insert them to the screw holes of the protection enclosure. It is to enhance
device reliability.
2.2.2 Manual Zoom Lens Focus Operation
The manual zoom lens focus interface is shown as in Figure 2-9.
Lock screw B/C
Adjust lens tilt rotation
angle.
Lock screw D
Adjust lens pan rotation
angle.