DH Network Camera
Product Construction Instruction Manual (Passenger Flow Solution)
22
Parameters
Description
Record
Select
Record
and when an alarm occurs, the system will
automatically record the alarm.
NOTE
Record Delay
When the alarm is over, the alarm recording will stop for an extended
period of time.
Alarm Output
Select
Relay-out
to start the alarm linkage output port. In case of an
alarm, the system links the corresponding relay-out device.
Alarm Delay
After an alarm finishes, the alarm is extended for a period of time and
stops.
Send Email
Select
Send Email
and the system emails you when an alarm is
triggered.
Snapshot
Select
Snapshot
and the system auto takes snapshot when an alarm
is triggered.
3. Calibration Config
Configure the installation height and angle of the device.
Select
Setup > Event > People Counting > Calibration Config.
The
Calibration Config
interface is displayed. See Figure 6 .
Figure 3-4
Calibration Config
Click
Clear
to remove the calibration frame.
Click
Ground
to draw a rectangle to frame the ground.
The device then calculates its height above the ground and the angle it forms with the ground.
Review
Height
and
Angle.
Click
Save
to complete the configurations.