Explosion-proof Integrated PTZ & Camera-
Instruction Manual
VI
Ex structure instruction
We have made adequate consideration in flameproof enclosure
design of the explosion-proof camera to prevent explosive gases
getting into the inner volume, the explosion inside the enclosure
cannot cause the explosion of the external explosive gases. We
ensure the explosion-proof performance by strengthen enclosure
the strength, adjust the length and gap of the joint of associate
components and limit the maximum surface temperature.
The enclosure is able to subject to static pressure test (2.0MPa
for at least 10s) specified in EN60079-01:2014/IEC60079-1: 2014,
no leakage or deformation allowed after test.
The maximum surface temperature will no more than 80ºC in
normal operation.
Tempering glass is adopted in observation port, the tempering
glass shall pass the impact and thermal shock test.
Ingress protection level: IP68(1.2m/45min).
Protection the flameproof surface in maintaining of this product,
otherwise the damaged flameproof surface will affect the
explosion-proof
performance