System Operation 23
3.8.3 Wiegand Configuration
Select
Wiegand Input
or
Wiegand Output
according to the entering direction and exiting
direction.
Select
Connection > Wiegand
, and then the Wiegand interface is displayed. See Figure 3-13.
Wiegand
Figure 3-13
Select
Wiegand Input
when an external card swipe mechanism is connected to the
terminal.
When
Serial Input
is selected to make the terminal be connected to the reader in the
turnstile, you need to select Door 1 or Door 2 as needed.
Door 1: If Door 1 is selected, then the reader and terminal control the same door
opening direction. For example, both the reader and terminal control the entering
direction into a place or all control the exiting direction from a place.
Door 2: If Door 2 is selected, the reader and terminal control different door opening
directions. For example, the terminal controls the entering direction into a place and
the reader controls the exiting direction from a place.
Select
Wiegand Output
when the terminal works as a reader that can be connected to the
controller. See Table 3-8.
Table 3-8 Wiegand output
Parameter
Description
Wiegand output type
The Wiegand Output Type determines the card number or the digit
of the number than can be recognized by the terminal.
Wiegand26, three bytes, six digits.
Wiegand34, four bytes, eight digits.
Wiegand66, eight bytes, sixteen digits.
Pulse Width
You can set pulse width and pulse interval.
Pulse Interval
Output Data Type
You can select the types of output data.
User ID: If User ID is selected, and then user ID will be output.
Card No.: If Card No. is selected, and then card number will be
output.
System
3.9
3.9.1 Time
You can do date format setting, date setting, time setting, DST setting, NTP check, time zone