background image

 

 

 

If the unit is damaged and requires service, unplug the unit from the main AC power supply and 

from the PoE supply and refer to qualified service personnel. Damage may include, but is not 

limited to: 

  The power supply cord or plug is damaged. 

  Liquid has spilled in or on the unit. 

  An object has fallen on the unit. 

  The unit has been dropped and the housing is damaged. 

  The unit displays a marked change in performance. 

  The unit does not operate in the expected manner when the user correctly follows the proper 

operating procedures. 

 

Ensure a service technician uses replacement parts specified by the manufacturer, or that have 

the same characteristics as the original parts. Unauthorized parts may cause fire, electrical 

shock, or other hazards. Dahua is not liable for any damage or harm caused by unauthorized 

modifications or repairs. 

 

Perform safety checks after completion of service or repairs to the unit.  

 

Use attachments and accessories only specified by the manufacturer. Any change or 

modification of the equipment, not expressly approved by Dahua, could void the warranty.  

 

Incorporate a readily accessible disconnect device in the building installation wiring for quick 

power disconnect to the camera. 

 

Dahua assumes no liability or responsibility for any fire or electrical shock caused by improper 

handling or installation.  

Environmental Precautions 

 

Do not aim the unit at a strong light source or into direct sunlight to focus. A strong light source 

may cause overexposure and may affect the longevity of the CCD or the CMOS sensor. 

 

Transport, use, and store the unit within the specified temperature and humidity range.  

 

Do not place the unit in a wet, dusty, extremely hot or an extremely cold environment; and avoid 

environments with strong electromagnetic radiation or unstable lighting.  

 

Never push objects of any kind into this unit through openings as they may touch dangerous 

voltage points or cause a short circuit that may result in fire or electrical shock. Take care to not 

spill any liquid on the unit.  

 

Do not use units intended for indoor applications near water, in damp or wet environments, or in 

any area classified as a wet location. Do not expose an indoor unit to rain or moisture to reduce 

the risk of fire or electric shock. 

 

Do not block or cover any openings in the unit enclosure. These openings are provided for 

ventilation to prevent overheating and to ensure reliable operation. Ensure the unit is placed in 

an area with adequate ventilation.  

 

Do not place the unit near a heat source such as heaters, stoves, radiators or other equipment 

that produces heat. 

 

Pack the unit with standard factory packaging or material of the same quality when transporting 

the unit.  

 

Take care to avoid heavy stress, violent vibration, or water spills to the camera unit during 

transportation, storage, and installation. 

Summary of Contents for 59230IC

Page 1: ...4 MP HDCVI PTZ Network Camera 59430IC 59230IC Quick Start Guide Version 001 001 Dahua Technology USA Inc ...

Page 2: ...al Notices 4 Copyright 4 Trademarks 4 1 4 Disclaimer 5 2 Unpacking 6 2 1 Parts List 6 2 2 User supplied Tools and Hardware 6 3 Installation and Configuration 7 3 1 Framework and Dimensions 7 3 2 Wiring 8 3 3 Alarm Setup 8 Alarm Input 8 Alarm Output Level Application 9 Alarm Output Switch Application 9 4 Device Installation 10 4 1 Cable Requirements 11 4 2 Preparing the Camera 11 Unpacking the Came...

Page 3: ...o protect the unit from damage especially in damp environments Protect the plug and power cord from foot traffic being pinched and its exit from the unit Units with or without an ON OFF switch have power supplied to the unit whenever the power cord is inserted into the power source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power di...

Page 4: ...ing or installation Environmental Precautions Do not aim the unit at a strong light source or into direct sunlight to focus A strong light source may cause overexposure and may affect the longevity of the CCD or the CMOS sensor Transport use and store the unit within the specified temperature and humidity range Do not place the unit in a wet dusty extremely hot or an extremely cold environment and...

Page 5: ...r wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove the dirt Stained with grease or fingerprints Use a soft cloth to wipe gently the water droplet or the oil from the dome cover Then use an oil free cotton cloth or paper soaked with alcohol or detergent to...

Page 6: ...tee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Page 7: ...ry information Dahua accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between this guide and the product described Dahua is not liable for any loss caused by installation operation or maintenance inconsistent with the information in this guide Video loss is inherent to all digital surveillance and recording devices therefore Dahua cannot ...

Page 8: ...o transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please refer to the enclosed CD for more details to view the detailed User s Manual and for configuration software 2 1 Parts List Package Item Quantity HDCVI PTZ Camera 1 AC24V 3A Power Supply 1 PFB300S Wall Mount 1 PFA110 Mount Adapter 1 Roll of Teflon Tape 1 PTZ Manu...

Page 9: ... Installation and Configuration 3 1 Framework and Dimensions The following figures show the dimensions of the device in mm in These images are intended as a reference only Figure 3 1 Dimensions for 59430IC ...

Page 10: ...ND RS485 Yellow RS485 A Orange RS485 B 3 3 Alarm Setup Certain devices support alarm inputs and outputs check your specific device for alarm capability Alarm Input Refer to Figure 3 3 for alarm input configuration The device collects that status of the alarm input port when the input signal is idle or grounded If the input signal is connected to the 3 3 V or it is idle then the device receives the...

Page 11: ... external pull up level is 5 V and the maximum port current is 5 mA Once the output increases the pull up resistance the alarm decreases the output voltage to the normal state low level at less than 0 8 V Figure 3 3 Alarm Output Switch Application The alarm output drives the external circuit with a maximum current of 30 mA and a maximum voltage of 5 V It is recommended to add a relay if the circui...

Page 12: ...ide a different permanently earthed metal conduits not supplied Warning Install external interconnecting cables in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I CSA C22 1 for CAN application and in accordance to local country codes for all other countries Branch circuit protection incorporating a 20 A 2 pole Listed Circuit Breaker or Branch Rated Fuses are re...

Page 13: ... balun required 720p 380 m 1246 72 ft 1080p 380 m 1246 72 ft 4 MP 200 m 656 17 ft 4 2 Preparing the Camera The HDCVI PTZ camera comes with the PFB300S Wall Mount and the PFA110 Mount Adapter the installer must supply the following hardware Four 4 bolts washers or other fastening hardware to secure the wall mount to the installation medium The hardware must be capable of supporting eight 8 times th...

Page 14: ...rimeter mounting holes 2 Pre drill the four perimeter holes as marked on the wall for the expansion bolts using a drill bit that is no wider than the expansion bolt 3 Drill a 50 mm approximately 2 in center hole to route the cables if necessary 4 Insert an expansion bolt into each pre drilled perimeter hole if necessary 5 Wrap several turns of Teflon tape around the threads on the PFA110 Mount Ada...

Page 15: ...he external enclosure to the inside hole of the adapter block and then push it to the end and then tighten the three M6 screws on the adapter block firmly Note Ensure the M6 screws are tightly fixed to secure the dome to the wall mount 10 Make the proper wiring connections and supply power to the camera Refer to Section 3 2 Wiring Note The video connection is covered by a heat shrink tube Once the...

Page 16: ...ology USA Inc 23 Hubble Irvine CA 92618 Tel 949 679 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change without notice ...