background image

 

  Foreword 

General 

This document mainly introduces installation and basic operation of IP audio indoor station. 

Safety Instructions 

The following categorized signal words with defined meaning might appear in the Manual

.

 

Signal Words 

Meaning 

 

Indicates a high potential hazard which, if not avoided, will result 

in death or serious injury. 

 

Indicates a medium or low potential hazard which, if not avoided, 

could result in slight or moderate injury. 

 

Indicates  a  potential  risk  which,  if  not  avoided,  could  result  in 

property damage, data loss, lower performance, or unpredictable 

result. 

 

Provides methods to help you solve a problem or save you time. 

 

Provides additional information as the emphasis and supplement 

to the text. 

Revision History 

No. 

Version   

Revision Content 

Release Date 

V1.0.0 

First release   

2017.10.18 

V1.0.1 

Change size 

2017.11.27 

V1.0.2 

Add privacy protection notice 

2018.05.23 

Privacy Protection Notice 

As the device user or data controller, you might collect personal data of others' such as face, 

fingerprints, car plate number, Email address, phone number, GPS and so on. You need to be 

in  compliance  with  the  local  privacy  protection  laws  and  regulations  to  protect  the  legitimate 

rights  and  interests  of  other  people  by  implementing  measures  include  but  not  limited  to: 

providing  clear  and  visible  identification  to  inform  data  subject  the  existence  of  surveillance 

area and providing related contact. 

About the Manual 

 

The  Manual  is  for  reference  only.  If  there  is  inconsistency  between  the  Manual  and  the 

actual product, the actual product shall prevail. 

Summary of Contents for VTH2201DW

Page 1: ...IP Audio Indoor Station Quick Start Guide V1 0 2 Please scan the QR code to view the user s manual...

Page 2: ...TP and TCP Ports Change default HTTP and TCP ports for systems These are the two ports used to communicate and to view video feeds remotely These ports can be changed to any set of numbers between 102...

Page 3: ...up with unwanted visitors If you manually forwarded the HTTP and TCP ports in your router modem this feature should be turned off regardless Disabling UPnP is recommended when the function is not use...

Page 4: ...P camera resides on should not be the same network as your public computer network This will prevent any visitors or unwanted guests from getting access to the same network the security system needs i...

Page 5: ...asis and supplement to the text Revision History No Version Revision Content Release Date 1 V1 0 0 First release 2017 10 18 2 V1 0 1 Change size 2017 11 27 3 V1 0 2 Add privacy protection notice 2018...

Page 6: ...the actual product and the Manual Please contact the customer service for the latest program and supplementary documentation There still might be deviation in technical data functions and operations d...

Page 7: ...event it from falling Please don t drip or splash liquids onto the device don t put on the device anything filled with liquids in order to prevent liquids from flowing into the device Please install t...

Page 8: ...TO Debugging 6 3 1 2 VTH Debugging 14 3 2 Debugging Verification 20 4 Functional Operation 21 4 1 Function of Talk with Management Center 21 4 1 1 Call Management Center 21 4 1 2 Call from Management...

Page 9: ...status Indicator light is off the device is normal 3 Speaker Audio output 4 SOS Press this key to call Management Center at once Plus Sign In call status press this key to increase talk volume In sta...

Page 10: ...talk and the corresponding VTO unlocks Plus Sign Call Key In standby status press Plus Sign Call Key to arm and disarm In disarmed status press this combination key to arm Indicator light flashes and...

Page 11: ...Press this key shortly to carry out voice broadcast of present IP address Press it for 5s and the device restores factory defaults Network Port Provide network communications and power supply functio...

Page 12: ...r direct sunlight environment In case of any abnormality after insertion of network cable and power on please unplug the network cable to cut off power supply at once Connect power supply again after...

Page 13: ...5 Figure 2 1...

Page 14: ...O and VTH no has been planned 3 1 Debugging Settings This device is used with VTO of SIP system Every VTO and VTH in the network shall be debugged 3 1 1 VTO Debugging 3 1 1 1 WEB Interface Initializat...

Page 15: ...WEB interface It shall be at least 8 characters and shall include at least two types of number letter and symbol Figure 3 2 Step 4 Select Email and enter your Email address This Email address is used...

Page 16: ...Login Log in the WEB interface of the device Default user name is admin Password is the one set during initialization 3 1 1 2 Modify IP Address of the Device Modify default IP address of VTO to the pl...

Page 17: ...o new IP login interface automatically If PC is not in the planned network segment the webpage cannot be displayed Please enter a new IP address in the browser 3 1 1 3 LAN Config Configure server type...

Page 18: ...plays SIP Server Config interface as shown in Figure 3 7 Figure 3 7 This VTO works as SIP server Tick Sip Server Enable and click OK to save the configuration VTO reboots automatically and WEB interfa...

Page 19: ...on has been completed If this VTO works as SIP server Device Manager will appear in the left parameter tab VTO and VTH shall be added For details please refer to Add VTO and 3 1 1 6 Add VTH 3 1 1 5 Ad...

Page 20: ...in WEB interface of this VTO Password Table 3 2 Step 5 Click OK to complete adding According to above operation add info about VTO in the network in sequence 3 1 1 6 Add VTH Add all VTH info 1 VTH sha...

Page 21: ...guish them First Name Nick Name VTH Short No Configure VTH room number VTH short no is consistent with room no on VTH device Sub VTH is represented with For example main VTH is 9901 sub VTH is 9901 1...

Page 22: ...o the system searches devices in current segment Default setting is Current Segment Search Other segment search tick Other Segment Search set Start IP End IP Username and Password so the system search...

Page 23: ...have not been initialized 2 Click The system displays Device Initialization interface as shown in Figure 3 14 Figure 3 14 3 Select the device that shall be initialized and click Initialize The system...

Page 24: ...Default username is admin New Password Enter new password of the device which consists of 6 numbers Confirm Password Confirm the new password Email Address It is ticked by default This Email address...

Page 25: ...l be displayed if initialization succeeded and will be displayed if initialization failed Click the icon to view details Figure 3 17 7 Click Complete to complete device initialization On completion de...

Page 26: ...nsistent with register password set when adding the device on SIP server VTO Password Password to log in VTO WEB interface Sip Realm When VTO works as SIP server realm name shall be VDP When the platf...

Page 27: ...in the template shall be filled according to network planning After importing and matching successfully the system will modify IP address of the device according to the filled content 3 In Project1 o...

Page 28: ...20 Figure 3 20 3 2 Debugging Verification Please refer to 4 1 Function of Talk with Management Center 4 2 Function of Talk with VTO and 4 3 Unlock Function verify whether VTH debugging has succeeded...

Page 29: ...all Key on the front panel to pick up the call and talk with each other Press Call Key again to hang up 4 2 Function of Talk with VTO When VTO calls VTH VTH rings Press Call Key on the front panel to...

Page 30: ...2 Disarm In arm status press Plus Sign Call Key to disarm The indicator light turns off and the device beeps twice 4 6 Alarm Prompt and Uploading Function The device is able to connect 4 zones at mos...

Page 31: ...nserted well confirm whether corresponding unit VTO works normally Q VTH doesn t ring when VTO calls How to deal with it A Please check whether DND function has been enabled Q How to deal with problem...

Page 32: ...nical Key 5 mechanical keys SOS plus sign call subtraction sign and unlock Alarm Alarm Input 4 channels Alarm Output 1 channel Installation Installation with bracket Specification Power Supply DC 12V...

Page 33: ...vices and documents are included in the packaging box Please check earnestly when opening the box and keep them properly Name Quantity Note Main Device 1 unit Quick Start Guide 1 guide Installation Sc...