User’s Manual
13
Parameter
Description
24 H Protection Zone
●
If
24 H Protection Zone
is enabled, even the system is
disarmed, the PIR can be armed and detects motion.
●
If
24 H Protection Zone
is disabled, only when the
system is armed, the PIR can be armed and detects
motion. The PIR will not be armed immediately, it will
begin before the end of the ping interval of the hub-
detector (60 seconds by default).
You can go to the hub's screen to configure the ping interval
of the hub-detector. For details, see the user's manual of the
hub.
Home Mode
Enable the home mode, and then the selected accessories
under the hub will be armed.
Delay Mode under Home Mode
Enable the
Delay Mode under Home Mode
, the selected
accessory under the hub will be armed and the alarm will not
be triggered until the end of customized delay time.
Only enable
Home Mode
first can
Delay Mode under Home
Mode
take effect.
Delay Time
●
The system provides you with time to leave or enter the
protection zone without alarm.
◇
Delay Time for Entering Arming Mode
: When you
enter the zone, if you do not disarm the system before
the delay ends, an alarm will be triggered.
Make sure that the delay time for entering arming
mode is no longer than 45 seconds in order to comply
with EN50131-1.
◇
Delay Time for Exiting Arming Mode
: When you are
in the zone and arm the system, if you do not leave
the zone before the delay ends, an alarm will be
triggered.
●
Select from 0 s to 120 s.
The arming mode will be effective after the delay time.
Sensitivity
●
Sensitivity level during a shock alarm.
●
Select from low, medium and high.
Siren Linkage
When an alarm is triggered, the accessories will report the
alarm events to the hub and alert with siren.
Alarm-video Linkage
When an alarm is triggered, the accessories will report the
alarm events to the hub and then will be linked with videos.