User’s Manual
376
section shall be more than 20mm
2
.
The ground cable of the monitor system cannot short circuit or mixed connected with the strong
alternative current cable.
For all the ground cables from the control room to the monitor system or ground cable of other
monitor devices, use the copper resistance soft cable and its section shall be more than 4 mm
2
.
The monitor system usually can adopt the one-point ground.
Connect the ground end of 3-pin socket in the monitor system to the ground port of the system
(protection ground cable)
Appendix 7.4
The Shortcut Way to Check the Electric System by
Digital Multimeter
For 220 VAC socket, from the top to the bottom, E (ground cable), N (neutral cable), L (live cable). Refer
to the following figure.
Appendix Figure 7-4
Socket
There is a shortcut way to check whether these three cables connection are standard or not (not the
accurate check).
In the following operations, the multimeter range shall be at 750 V.
For E (earth cable)
Turn the digital multimeter to 750 VAC, use your one hand to hold the metal end, and then the other
hand inserts the pen to the E port of the socket. See the following figure. If the multimeter shows 0,
then you can see current earth cable connection is standard. If the value is more than 10, then you can
know there is inductive current and the earth cable connection is not proper.
Summary of Contents for DH-XVR58 S-4KL-I2-LP Series
Page 1: ...AI Digital Video Recorder User s Manual V2 2 0 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD...
Page 187: ...User s Manual 177 Details Click Register ID Register ID Click to add a face picture...
Page 238: ...User s Manual 228 Details Click Register ID Register ID Click to add a face picture...
Page 314: ...User s Manual 304 Main stream Sub stream...
Page 317: ...User s Manual 307 Version 1 Version 2...
Page 362: ...User s Manual 352 Legal information...
Page 388: ...User s Manual 378 Appendix Figure 7 7 Check neutral cable connection...
Page 394: ...User s Manual...