background image

Quick Start Guide 

III 

  You can clean the device body with soft dry cloth, and for stubborn stains, use the cloth with 

mild detergent. To avoid possible damage on device body coating which could cause 
performance decrease, do not use volatile solvent such as alcohol, benzene, diluent and so on to 
clean the device body, nor can strong, abrasive detergent be used. 

  Dome cover is an optical component. Do not touch or wipe the cover with your hands directly 

during installation or operation. For removing dust, grease or fingerprints, wipe gently with 
moistened oil-free cotton with diethyl or moisten soft cloth. You can also remove dust with an air 
blower. 

 

  Strengthen the protection of network, device data and personal information by adopting 

measures which include but not limited to using strong password, modifying password regularly, 
upgrading firmware to the latest version, and isolating computer network. For some device with 
old firmware versions, the ONVIF password will not be modified automatically along with the 
modification of the system password, and you need to upgrade the firmware or manually update 
the ONVIF password. 

  Use standard components or accessories provided by manufacturer and make sure that the 

device is installed and maintained by professional engineers. 

  The surface of the image sensor should not be exposed to laser beam radiation in an 

environment where a laser beam device is used. 

  Do not provide two or more power supply sources for the device unless otherwise specified. A 

failure to follow this instruction might cause damage to the device. 

Summary of Contents for DH-PSDW8842ML-A180-D237

Page 1: ...Multi Sensor Panoramic Network PTZ Camera Quick Start Guide V1 0 1...

Page 2: ...ted according to the latest laws and regulations of related jurisdictions For detailed information refer to the paper manual CD ROM QR code or our official website If there is inconsistency between pa...

Page 3: ...ion Transport use and store the device within the range of allowed humidity and temperature Heavy stress violent vibration or water splash are not allowed during transportation storage and installatio...

Page 4: ...k device data and personal information by adopting measures which include but not limited to using strong password modifying password regularly upgrading firmware to the latest version and isolating c...

Page 5: ...dress 6 3 3 Logging in to Web Interface 6 4 Smart Track Configuration 8 4 1 Enabling Alarm Track 8 4 2 Configuring calibration parameter 8 5 Installation 11 5 1 Packing List 11 5 2 Dimensions 11 5 3 I...

Page 6: ...partial details Panoramic camera can provide real time HD surveillance of 180 270 360 view coverage Besides it is convenient to recognize and exclude abnormity via quick positioning and zoom in of tr...

Page 7: ...nnection Yellow and green Ground connection Device abnormity or damage could occur if power is not supplied correctly 2 RS 485 port Reserved port 3 Video output BNC port Connects to TV monitor to chec...

Page 8: ...nection For more information about I O port see Table 2 3 Table 2 3 Alarm information Port Port Name Description Alarm I O ALARM_OUT Outputs alarm signal to alarm device When connecting to alarm devic...

Page 9: ...nd the PC stays in the same network segment Plan usable network segment properly to connect the device to the network The following figures and interfaces are for reference only and the actual product...

Page 10: ...ing Step 7 Set and confirm the password of the devices then enter a valid email address and then click Next The final setting interface is displayed Password can be modified or reset in System Setting...

Page 11: ...therwise there will be wrong password notice Step 2 Select the devices whose IP addresses need to be modified and then click Modify IP The Modify IP Address interface is displayed Figure 3 3 Modify IP...

Page 12: ...password in the login box and then click Login Step 3 For the first time login click Click Here to Download Plugin and then install the plugin as instructed The main interface is displayed when the i...

Page 13: ...y default and you need to enable it manually Step 1 Select Setting Event Smart Track Alarm Track Step 2 Click On to enable Alarm Track For details see Web Operation Manual Figure 4 1 Alarm track 4 2 C...

Page 14: ...nual calibration Select Manual in Calibration Mode select the lens that you need and then add calibration point for it in the live image Interface might vary with different models and the actual inter...

Page 15: ...lens and then click The calibration boxes are displayed in both images 2 Pair each box in the two images and keep the paired boxes at the same spot of the live view 3 Click You need at least 4 pairs...

Page 16: ...l is not provided in the package The operation manual and related tool information are contained in the disk or the QR code and the actual package shall prevail Figure 5 1 Packing list 5 2 Dimensions...

Page 17: ...Camera 5 3 1 Installation Method Figure 5 3 Installation method 5 3 2 Installing SD Card Optional SD card slot is available on select models Disconnect the power before installing or removing the SD...

Page 18: ...Quick Start Guide 13 5 3 3 Attaching Camera Make sure that the mounting surface is strong enough to hold at least three times of the weight of the device and bracket...

Page 19: ...Quick Start Guide 14 Figure 5 5 Cable going through the side cable tray...

Page 20: ...Waterproof Connector Optional This part is needed only when there is waterproof connector in the package and the device is used outdoors Figure 5 6 Installing waterproof connector 5 3 5 Adjusting Lens...

Page 21: ...Quick Start Guide...

Reviews: