Page 8
Return to Master Table of Contents
TORQUE VALUES FOR SPLIT FLANGES
The following chart provides the tightening torques for split flange connections used in hydraulic systems.
Split flanges and fitting shoulders should fit squarely. Install all bolts, finger tight and then torque evenly.
NOTE:
Overtorquing bolts will damage the flanges and/or bolts, which may cause leakage.
(*) - Inside diameter of flange on end of hydraulic tube or hose fitting.
NOTE:
Values stated in chart are for Standard Pressure Series (Code 61) Split Flanges.
FLANGE
SIZE (*)
BOLT
SIZE
BOLT TORQUE
KILOGRAM METER
(kg•m)
FOOT POUNDS
(Ft. Lbs.)
1/2"
3/4"
1"
1 - 1/4"
1 - 1/2"
2"
2 - 1/2"
3"
3 - 1/2"
5/16"
3/8"
3/8"
7/16"
1/2"
1/2"
1/2"
5/8"
5/8"
2.1 - 2.5
3.0 - 3.7
3.7 - 4.8
4.8 - 6.2
6.4 - 8.0
7.6 - 9.0
10.9 - 12.6
19.1 - 20.7
16.2 - 18.4
15 - 18
22 - 27
27 - 35
35 - 45
46 - 58
55 - 65
79 - 91
138 - 150
117 - 133
Summary of Contents for Solar 200W-V
Page 1: ...Shop Manual 2023 7139E Serial Number 0001 and Up March 2000 Solar 200W V...
Page 3: ......
Page 6: ...Return to Master Table of Contents 1SAFETY...
Page 28: ...S0102020 Page 22 Wheel Excavator Safety Return to Master Table of Contents...
Page 29: ...Return to Master Table of Contents 1SPECIFICATIONS...
Page 30: ...Return to Master Table of Contents...
Page 37: ...S0202040 Page 7 Specifications for Solar 200W V Return to Master Table of Contents...
Page 57: ...Return to Master Table of Contents 1GENERAL MAINTENANCE...
Page 58: ...Return to Master Table of Contents...
Page 72: ...S0302000 Page 14 General Maintenance Procedures Return to Master Table of Contents...
Page 85: ...Return to Master Table of Contents 1UPPER STRUCTURE...