58
• situation : PCB shows "E3".
cause)
☞
FAN MOTOR can not work.
countermeasures)
☞
Replace the Fan Motor.
part name
checking results
repair method
disassemble process of Fan Motor
FAN MOTOR
fan motor failure
replace
fan motor
1
Disassemble Duct Cover As from Duct B As
(Screw 4EA)
2
Disassemble FAN AS From Duct Cover As
(Fixed by 8mm NUT)
3
Disassemble the FAN MOTOR(SCREW 3EA)
parts
Control time
MOTOR
15 sec On, 5sec Off
DRAIN MOTOR
Continous working
FAN MOTOR
Continous working
DRY HEATER
95°C On, 105°C Off
INLET VALVE
30sec On, 5sec Off
Remarks) control times of each parts during dry process
DUCT COVER AS
Fixed By 8mm NUT
Summary of Contents for KUD-UD121DCR
Page 1: ...Service Manual Model KUD UD121DCR Auto Washer Dry KUD UD121WCW...
Page 14: ...13 3 CABINET F ASSY...
Page 16: ...15 4 CABINET ASSY...
Page 18: ...17 5 BASE U AS...
Page 20: ...19 6 TUB ASSY F22...
Page 22: ...21 7 DUCT B AS DUCT PIPE AS...
Page 65: ...63 1 Structure of BLDC Motor 7 HEATER bldc motor 2 Power Transmission System of BLDC Motor...
Page 67: ...65 8 WIRINGDIAGRAM...