37
6-1. IE (Input Error) - Error in water supply
1) Conditions of Occurrence
ῡ
In case the designated water level is not reached in 5 minutes during water supply or re-supply
2) All LEDs are turned off and 'IE' blinks in18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-2. OE (Output Error) - Error in drainage
1) Conditions of Occurrence
ῡ
In case water level does not reach reset point in 10 minutes after drainage starts
2) All LEDs are turned off and 'OE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-3. UE (Unbalance Error)
1) Conditions of Occurrence
ῡ
In case main spin-drying is not reached within 20 cycles of balance spin-drying
ῢ
In case balance spin-drying fails during interim spin-drying, UE occurs as the cycle moves to the next
process.
2) All LEDs are turned off and 'UE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error mode is cleared by opening door and organizing the laundry in spin-dry chamber, closing door and
pressing start/ temporary stop button. Then, spin-drying begins again.
6-1. Error Display
Summary of Contents for KUD-UD121DCR
Page 1: ...Service Manual Model KUD UD121DCR Auto Washer Dry KUD UD121WCW...
Page 14: ...13 3 CABINET F ASSY...
Page 16: ...15 4 CABINET ASSY...
Page 18: ...17 5 BASE U AS...
Page 20: ...19 6 TUB ASSY F22...
Page 22: ...21 7 DUCT B AS DUCT PIPE AS...
Page 65: ...63 1 Structure of BLDC Motor 7 HEATER bldc motor 2 Power Transmission System of BLDC Motor...
Page 67: ...65 8 WIRINGDIAGRAM...