25
POWER LEVEL
OUTPUT POWER
RELAY “1” TURN ON, OFF TIME
AGAINST FULL POWER
1
5/29
2
11/29
3
17/29
4
23/29
5
29/29
AUTO DEFROST CYCLE
When auto defrost is selected and the desired defrosting time is chosen, the automatic cycle divides the
defrosting time into 5 periods of alternating defrost and stand times, by cycling on and off.
4. When the door is opened during cooking.
1) The primary interlock switch is opened to cut off primary voltage to the high voltage transformer to
stop microwave oscillation.
2) The secondary interlock switch is opened to give the door open information to touch control circuit.
The contacts of the RELAY “1” and “2” open, the display stops counting down.
3) Fan motor and turn table stop rotating.
4) The oven lamp turns off.
5) As soon as the door is opened, the interlock monitor switch contacts close and creats the short
circuit.
6) If the contacts of primary interlock switch malfunction the 12A fuse blows open due to the large
current surge caused by the short circuit activation, and this in turn stops magnetron oscillation
(Fig. 1).
5. When the STOP/CLEAR button is touched during cooking.
1) The touch control circuit cuts the voltage supplied to the RELAY “1” coil and causes the magnetron
to stop oscillating.
2) RELAY “2” turns off.
3) The display will show the time of day. If you don’t set the clock, the display will show a colon.
4) The oven lamp turns off.
5) Fan motor and turn table motor stop rotating.
ON
OFF
5S
ON
OFF
11S
ON
OFF
17S
ON
OFF
23S
ON
OFF
29S
Fig. 3
Summary of Contents for KOR-616T2S
Page 1: ...Service Manual Microwave Oven Model KOR 616T2S KOR 816T2S DAEWOO ELECTRONICS CO LTD...
Page 42: ...41 FIG 5 MEASUREMENT POINT MP2 MP3 MP1...
Page 43: ...42 FIG 5 MEASUREMENT POINT...
Page 46: ...1 PCB Circuit Diagram 45 2 P C B CIRCUIT DIAGRAM...
Page 48: ...47 3 PRINTED CIRCUITS BOARD...
Page 49: ...48...
Page 54: ...53 3 Main Unit...