17
6. To remove control panel parts.
(1) Remove the screw which secure the control panel, push up two snap fits and draw forward the control panel assembly.
(2) Remove the door open lever from the control panel.
(3) Remove four screws which secure the PCB assembly to control panel.
(4) Disconnect membrane tail from the connector of the PCB assembly.
(5) Detach membrane from the control panel.
(6) Remove door open button and button spring from the control panel.
(7) Reverse the above steps for reassembly.
REF NO.
PART CODE
PART NAME
DESCRIPTION
Q’TY
B01
3518524400
SWITCH MEMBRANE
KOG-867T9
1
B02
3516731100
CONTROL PANEL
ABS VE-0826 AF-348
1
B03
PKMPMSAY00
PCB AS
KOG-867T9
1
B04
7122401211
SCREW TAPPING
T2S TRS 4X12 MFZN
4
B05
3513702700
LEVER DOOR LOCK
PP
1
B06
441G430171
BUTTON SPRING
SWP DIA 0.7
1
B07
3516912300
BUTTON DOOR OPEN
ABS SG-175 SG-0760D
1
✔
Caution:
In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the
latest parts information, please refer to PPL(Parts Price List) in Service information Center(http://svc.dwe.co.kr)