background image

3. COMPONENT TEST PROCEDURE

 High voltage is present at the high voltage terminal of the high voltage transformer during any cooking cycle.
 It is neither necessary nor advisable to attempt measurement of the high voltage.
 Before touching any oven components or wiring, always unplug the oven from its power source and discharge the

capacitor.

1. High voltage transformer

(1) Remove connections from the transformer terminals and check continuity.
(2) Normal readings should be as follows(at 20 C):

Secondary winding

.....................Approx. 170     10%

Filament winding....................................Approx. 0 
Primary winding .........................Approx. 2.5  10% 

2. High voltage capacitor

(1) Check continuity of capacitor with meter on the highest OHM scale.
(2) A normal capacitor will show continuity for a short time, and then indicate 10M  once the capacitor is charged.
(3) A shorted capacitor will show continuous continuity.
(4) An open capacitor will show constant 10M  .
(5) Resistance between each terminal and chassis should be infinite.

3. High voltage diode

(1) Isolate the diode from the circuit  by disconnecting the leads.
(2) With the ohmmeter set on the highest resistance scale measure the resistance across the diode terminals.

Reverse the meter leads and again observe the resistance reading. 
Meter with 6V, 9V or higher voltage batteries should be used to check the front-back resistance of the diode, oth-
erwise an infinite resistance may be read in both directions. 
A normal diode s resistance will be infinite in one direction and several hundred K

in the other direction.

4. Magnetron

For complete magnetron diagnosis, refer to  Measurement of the Microwave Power Output .
Continuity checks can only indicate and open filament or a shorted magnetron. 
To diagnose for an open filament or a shorted magnetron.

(1) Isolate magnetron from the circuit by disconnecting the leads.
(2) A continuity check across magnetron filament terminals should indicate 0.1  or less.
(3) A continuity check between each filament terminal and magnetron case should read open.

5. Fuse

If the fuse in the primary and monitor switch circuit is blown when the door is opened, check the primary and monitor
switch before replacing the blown fuse.
In case the fuse is blown by an improper switch operation, replace the defective switch and fuse at the same time.
Replace just the fuse if the switches operate normally.

22

Summary of Contents for KOG-6C675S

Page 1: ...C675S001 http svc dwe co kr Jan 2004 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information pleas...

Page 2: ...s d Any defective or misadjusted components in the interlock monitor door seal and microwave generation and transmission systems shall be repaired replaced or adjusted by procedures described in this...

Page 3: ...oven unit is found to servicing a microwave emission check should be performed prior to servicing the oven a inform the manufacturer importer or assembler b repair the unit at no cost to the owner c...

Page 4: ...W COMBINATION 2200 W MICROWAVE ENERGY OUTPUT 800W MICROWAVE FREQUENCY 2450MHz OUTSIDE DIMENSIONS WXHXD 465 x 279 x 384mm CAVITY DIMENSIONS WXHXD 290 x 220 x 306mm NET WEIGHT APPROX 13 4Kg TIMER 35 min...

Page 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION 465 384...

Page 6: ...enter of the ovens cavity floor This is to remain in the oven for all cooking 0 Roller guide This must always be used for cooking together with the glass cooking tray q Glass cooking tray Made of spec...

Page 7: ...with cable of same type Such a cable can be purchased from DAEWOO and must be installed by a qualified person 6 Examine the oven after unpacking for any damage such as A misaligned door broken door or...

Page 8: ...ave energy will be turned off auto matically when the timer reaches OFF Then food can be taken out of the oven To prevent the oven from operating with the door open your microwave oven is fitted with...

Page 9: ...work 2 Warning about the electric charge in the high voltage capacitor For about 30 seconds after the operation stopped and electric charge remains in the high voltage capacitor When replacing or che...

Page 10: ...rd 2 To remove door assembly 1 Remove a screw which secure the stopper hinge top 2 Remove the door assembly from top plate of cavity 3 Reverse the above for reassembly NOTE After replacing the door as...

Page 11: ...R ABS SG 175 SG 0760D 1 3 To remove door parts 1 Remove the gasket door from door weld as 2 Remove the gasket door from door weld as 3 Remove the door frame from door weld as 4 Remove the stopper hing...

Page 12: ...top and then push the door to contact the door seal to oven front surface Tighten a screw 2 To reduce gap located on part B Loosen two screws on stopper hinge under and then push the door to contact...

Page 13: ...760D 1 B17 3515101600 SPRING FLAT SUS 301 T0 5 1 5 To remove control panel parts 1 Remove the screw which secure the control panel push up two snap fits and draw forward the control panel assembly 2 R...

Page 14: ...emove a screw which secure the magnetron 2 Remove the magnetron 3 Reverse the above steps for reassembly NOTE Never install the magnetron without the metallic gasket plate which is packed with each ma...

Page 15: ...e wind guide assembly 1 Remove a screw for earthing 2 Remove the noise filter from the wind guide 3 Remove a screw which secure the wind guide assembly 4 Draw forward the wind guide assembly 5 Pull th...

Page 16: ...e plate 4 Remove the tray motor cover 5 Remove a screw which secure the tray motor 6 Remove the tray motor 7 Reverse the above steps for reassembly except for securing the tray motor cover with screw...

Page 17: ...ATER 230V 1000W 1R67994001 1 C05 7002500613 SCREW MACHINE TRS 5X6 MFCR 1 C06 7002400413 SCREW MACHINE TRS 4X4 MFCR 1 12 To remove heater parts Caution In this Service Manual some parts can be changed...

Page 18: ...downward The lock lever presses the button of the interlock monitor switch to bring it under NO condition and presses the button of the secondary interlock switch to bring it under ON condition 3 Adju...

Page 19: ...or work when you shut the door and turn the timer YES If outlet has proper voltage check continuity of power supply cord Replace power supply cord NO Continuity Check continuity of interlock monitor s...

Page 20: ...able motor NO If microwave do not oscillate check continuity of filament of magnetron Poor continuity NO Continuity Check continuity filament tap 3 3V of high voltage Replace high voltage transformer...

Page 21: ...l the load is immediately placed on the center of the shelf which is in the lowest normal position 4 Microwave power is switched on 5 Heating time should be exactly A seconds Refer to table as followi...

Page 22: ...binet door seem door viewing screen the exhaust air vents and the suction air vents 3 Measuring should be in a counter clockwise direction at a rate of 1 in sec If the leakage of the cabinet door seem...

Page 23: ...mmeter set on the highest resistance scale measure the resistance across the diode terminals Reverse the meter leads and again observe the resistance reading Meter with 6V 9V or higher voltage batteri...

Page 24: ...23 WIRING DIAGRAM...

Page 25: ...1 DOOR ASSEMBLY Refer to Disassembly and assembly 2 CONTROL PANEL ASSEMBLY Refer to Disassembly and assembly 3 TOTAL ASSEMBLY EXPLODED VIEW AND PARTS LIST 24...

Page 26: ...EX 4X8 FLG MFZN 4 F25 3510311700 BASE SBHG T0 7 1 F26 7112401011 SCREW TAPPING T1 TRS 4 10 MFZN 5 F27 3512100900 FOOT PP DASF 130 2 F28 7272400811 SCREW TAPTITE TT3 TRS 4X8 MFZN 1 F29 3515201101 STOPP...

Page 27: ...S M NO G6C675S001 DAEWOO ELECTRONICS CORP 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC PRINTED DATE Jan 2004...

Reviews: