1. High voltage is present at the high voltage terminal of the high voltage transformer during any cooking cycle.

2. It is neither necessary nor advisable to attempt measurement of the high voltage.

3. Before touching any oven components or wiring, always unplug the oven from its power source and discharge

the capacitor (see page 14).

5. Interlock monitor switch

The interlock switch can be checked with an ohmmeter. Isolate the switch and then connect the meter leads to the
common (COM) and normally close (NC) terminals of the switch. The meter should indicate an open circuit with
the door closed and a closed circuit with the door opened.
In case improper operation is indicated, make the necessary switch adjustment or replacement.

6. Primary and secondary interlock switch

The primary and secondary interlock switch can be checked with an ohmmeter. Isolate the switch and connect the
meter leads to the common (COM) and normally open (NO) terminals of the switch.
The meter should indicate an open circuit with the door opened and a closed circuit with the door closed. In case
improper operation is indicated, make the necessary switch adjustment or replacement.

COMPONENT TEST PROCEDURE

1. High voltage transformer

(A) Remove connections from the transformer

terminals and check continuity.

(B) Normal readings should be as follows:

Secondary winding........Approx. 120

¡

10%

Filament winding ...........................Approx. 0

Primary winding.............................Approx. 0

2. High voltage capacitor

(A) Check continuity of capacitor with meter on the

highest OHM scale.

(B) A normal capacitor will show continuity for a short

time, and then indicate 9M

once the capacitor is

charged.

(C) A shorted capacitor will show continuous

continuity.

(D) An open capacitor will show constant 9M

.

(E) Resistance between each terminal and chassis

should be infinite.

3. High voltage diode

(A) Isolate the diode from the circuit by disconnecting

the leads.

(B) With the ohmmeter set on the highest resistance

scale, measure the resistance across the diode
terminals.
Reverse the meter leads and again observe the
resistance reading. meter with 6V, 9V or higher
voltage batteries should be used to check the
front-back resistance of the diode, otherwise an
infinite resistance may be read in both directions.
A normal diodes resistance will be infinite in one
direction and several hundred K

in the other

direction.

4. Magnetron

For complete magnetron diagnosis, refer to
“Measurement of the Microwave Output Power”.
(Page 7) Continuity checks can only indicate and
open filament or a shorted magnetron. To diagnose
for an open filament or shorted magnetron.

(A) Isolate magnetron from the circuit by disconecting

the leads.

(B) A continuity check across magnetron filament

terminals should indicate ohm or less.

(C) A continuity check between each filament terminal

and magnetron case should read open.

Summary of Contents for KOG-36052S

Page 1: ...Service Manual Microwave Oven Model KOG 36052S KOG 36152S KOG 36252S KOG 36352S KOG 36452S DAEWOO ELECTRONICS CO LTD...

Page 2: ...avity for proper alignment integrity and connection d Any defective or misadjusted components in the interlock monitor door seal and microwave generation and transmission systems shall be repaired rep...

Page 3: ...make repairs 1 A broken door hinge 2 A broken door viewing screen 3 A broken front panel oven cavity 4 A loosened door lock 5 A broken door lock The door seal area and oven cavity surface be kept clea...

Page 4: ...GRILL 1050 W COMBINATION 2200 W MICROWAVE ENERGY OUTPUT 800 W MICROWAVE FREQUENCY 2450 MHz OUTSIDE DIMENSIONS WXHXD 465X360X274 mm KOG 36050S 36150S CAVITY DIMENSIONS WXHXD 290X290X220mm NET WEIGHT 1...

Page 5: ...e of special heat resistant glass Food in a proper receptacle is placed on this tray for cooking Roller Guide This must always be used for cooking together with the glass cooking tray Coupler this fit...

Page 6: ...bout 1 0 meters long Do not use an extension cord If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard...

Page 7: ...set at any time during the cooking cycle by only turning the timer knob Do not let the timer continue to operate after removing food 7 NOTE When using the GRILL KOG 368 9 OS mode Do not open the door...

Page 8: ...immediately before the water is added to the vessel After addition of the water to the vessel the load is immediately placed on the center of the shelf which is in the lowest normal position 4 Microw...

Page 9: ...Place it at the center of the tray and set it in a cavity D Close the door and operate the oven E Measure the leakage by using microwave energy survery meter with dual ranges set to 2450 MHz Measured...

Page 10: ...10 WIRING DIAGRAM SLOW ACTING RELAY...

Page 11: ...11 WIRING DIAGRAM...

Page 12: ...tae transformer and this secondary voltage is increased by the action of the diode and the charging of the high voltage capacitor This resultant D C voltage is then applied to the anode of the magnetr...

Page 13: ...o the high voltage transformer to stop microwave oscillation Fan motor timer motor and turntable motor stop rotating Oven lamp turn off As soon as the door is opened monitor switch close NC to create...

Page 14: ...epair work 2 Warning about the electric charge in the high voltage capacitor For about 30 seconds after the operation stopped and electric charge remains in the high voltage capacitor When replacing o...

Page 15: ...nge top 2 Remove the stopper hinge top and door assembly from top plate of cavity 3 Remove the stopper hinge top from door assembly 4 Reverse the above for reassembly taking care to replace fixing glu...

Page 16: ...three screws on bottom hinge and then the door to contact the door seal to oven front surface 2 Tighten three screws 3 To reduce gap locatated on part C See Fig A 1 Loosen a screw on the interlock sw...

Page 17: ...timer assembly 5 Pull out the timer knob from the timer assembly 6 Pull out the timer coupler from the timer assembly 7 Remove the screw pull out the switch micro 8 Remove the screw which secure the V...

Page 18: ...pacitor holder 2 Remove the H V diode from the capacitor holder 3 Reverse the above steps for reassembly High voltage circuit wiring 7 To remove magnetron 1 Remove three screws which secure the magnet...

Page 19: ...nsformer 2 Remove the transformer 3 Reverse the above steps for reassembly CAUTION Never install the magnetron without the metallic gasket plate which is packed with each magnetron to prevent microwav...

Page 20: ...2 3 4 5 6 7 3513301100 3512801700 7002500613 7392500008 7002400413 3515000700 7S627W50X1 1 1 1 1 2 2 2 SPP T0 8 230V 1000W TRS 5X6 MFCR 6N 2 5 SUS TRS 4X4 MFCR C3771BD FLG NUT M5X0 8P MFZN INSULATOR H...

Page 21: ...d the hook locks the oven door If the door is not closed properly the oven will not operate When the door is closed the hook pushes the button of the micro switch Then the button of the primary interl...

Page 22: ...he two mounting screws b Adjust interlock switch assembly position c Confirm the gap 1 2mm described above d Make sure that push lever moves smoothly after adjustments is completed e Completely tighte...

Page 23: ...nterlock switch secondary interlock switch and interlock monitor switch All these switches must be replace at the same time Replace H V T Thermal cut out Outlet has Proper voltage Check continuity of...

Page 24: ...he contacts of a relay operate oven Normal reading should be approx 0 Meter with 6V or higher voltage batteries should be used to check the normal direction resistance of the diode NO GOOD Poor contin...

Page 25: ...readings should be as follows Secondary winding Approx 120 10 Filament winding Approx 0 Primary winding Approx 0 2 High voltage capacitor A Check continuity of capacitor with meter on the highest OHM...

Page 26: ...e ohmmeter Fig a Condition 1 Door is opened 2 Common terminal of the monitor switch disconnected 3 In case of secondary interlock switch Lamp on or zero resistance ohmmeter Fig c Condition 1 Door is c...

Page 27: ...G 3645 3512202500 1 KOG 3605 A2 3512202000 1 KOG 3615 35 3512202010 FRAME DOOR ABS 1 KOG 3625 3512202800 1 KOG 3645 A3 3515201500 STOPPER HINGE T AS KOR 61150S 1 A4 3511705500 DOOR WELD AS KOR 61150S...

Page 28: ...645 B6 4415A66910 SW MICRO VP 531A OF 1 B7 7121301511 SCREW TAPPING T2S PAN 3X15 MFZN 1 B8 4415A17352 SW MICRO VP 533A OF 1 B9 7121301511 SCREW TAPPING T2S PAN 3X15 MFZN 1 B10 3517400500 COUPLER VPC K...

Page 29: ...29 3 Main Unit...

Page 30: ...F22 SCREW TAPPING 7S312X40A1 T1 TRS 4X10 SE MFZN 2 F23 SCREW MATCHINE 7601400811 PAN 4X8 PW MFZN 2 F24 COVER B 3511402500 SBHG T0 8 1 F25 MOTOR SHADED POLE 3963512100 MW10CA R01 1 F26 FAN 3511800300...

Page 31: ...S001 DAEWOO ELECTRONICS CO LTD 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC FAX 02 360 8184 TEL 02 360 8183 http www dwe daewoo co kr PRINTED D...

Reviews: