39
6. Case of no stopping of the count down timer
When the door is opened during operation, the count down timer does not stop.
(KOC-9N2T7S/R)
(KOC-9N3T7S/R)
POINT
STATE
DOOR OPEN
DOOR CLOSED
A
OPEN
CLOSE
B
+5V DC
GND
CN1
2
1
D6
+5V
R3
C1
15
R4
A
B
D.O.M SW
CHECK NO
METHOD
REMEDY
Check the stage(ON,OFF) of the door open
1
monitor switch by resistance
Replace door open monitor swith.
measurement.
CN1
1
2
C5
+5V
R9
C9
3
R10
A
B
D.O.M SW
R11
D6
Summary of Contents for KOC-9N2T7S
Page 5: ...3 EXTERNAL VIEW 1 OUTER DIMENSION 542 503 329 4 ...
Page 30: ...29 10 WIRING DIAGRAM ...
Page 36: ...35 MEASURE POINT OF KOC 9N2T7S R MP1 GND MP2 ...
Page 37: ...36 MP1 GND MP2 MEASURE POINT OF KOC 9N3T7S R ...
Page 41: ...40 13 P C B CIRCUIT DIAGRAM KOC 9N2T7S R ...
Page 42: ...41 KOC 9N3T7S R ...