21
CONDITION
CHECK
Check continuity of
magnetron
Defective
magnetron.
RESULT
No
continuity
CAUSE
REMEDY
Replace
Outlet has
proper
voltage
fuse does not
blow?
Check continuity of noise filter
board
Defective line
filter board
No
continuity
Replace
Check continuity of
power supply cord
Defective touch
control circuit
Replace
Open power
supply cord
No
continuity
No
continuity
Replace
NOTE : All these switches must be replaced at the same time, please refer to (7.Interlock mechanism and
adjust) for adjustment instructions
(TROUBLE 2)
Display shows all figures selected, but oven does not start cooking, even though desired program and time
are set and start button is tapped.
CONDITION
CHECK
Check continuity of
primary interlock switch
Malfunction of
primary interlock
switch
RESULT
No
continuity
CAUSE
REMEDY
Adjust or
replace
Turn table
motor and
oven lamp
do
not turn on
Check D.C voltage
being supplied to
RELAY(RY4) coil
Fault contacts
of RELAY
(RY4) or open
relay coil.
Replace
Check continuity of
secondary interlock
and D.O.M switch
Malfunction of
secondary
Interlock and
D.O.M switch
No
continuity
Adjust or
replace
Defective touch
control Circuit
0V
Approx.
24V DC
Replace
✔
Caution
:
In this Manual, some parts can be changed for improving, their performance without notice in the
parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List) in Service
Information Center (http://svc.dwe.co.kr).
Summary of Contents for KOC-9N2T7S
Page 5: ...3 EXTERNAL VIEW 1 OUTER DIMENSION 542 503 329 4 ...
Page 30: ...29 10 WIRING DIAGRAM ...
Page 36: ...35 MEASURE POINT OF KOC 9N2T7S R MP1 GND MP2 ...
Page 37: ...36 MP1 GND MP2 MEASURE POINT OF KOC 9N3T7S R ...
Page 41: ...40 13 P C B CIRCUIT DIAGRAM KOC 9N2T7S R ...
Page 42: ...41 KOC 9N3T7S R ...