Defrosting Mode
INPUT
Control Object
1. Defrosting Cycle
1. COMP
2. F-FAN
3. R-FAN
4. HEATER
CONTENTS
REMARKS
1. Defrosting Mode
1) Time ; 50 minutes
2) Comp. / F-fan : ON
R-fan : Control
Heater : OFF
3) If F-sensor < - 27C, PRE-COOL becomes OFF.
1) If D-sensor > 10C, Heater becomes OFF.
2) In case of Heater return by time limit of 40 or 80 min
(F3-Error)
3) Heater is ON for 30 minutes (time limit) in case of D-
sensor error.
4) Time limit
a. 30 seconds : Heater is ON regardless of D-sensor
temperature right after defrosting start.
b. 30 minutes : in case of D1-Error
c. 80 minutes : in normal control state
1) Time : 7 minutes
Comp., F-fan, R-fan, Heater : OFF
1) Time : 5 minutes
Comp. : ON
F/R-fan, Heater : OFF
* Output control and time limit of each defrosting mode
PRE-COOL
Heater Defrosting
Pause
Fan
Delay
COMP
ON
OFF
OFF
ON
F-FAN
ON
OFF
OFF
OFF
R-FAN
Control
OFF
OFF
OFF
HEATER
OFF
ON
OFF
OFF
Time Limit
50 min.
a. 80 min.
b. 30 min.
(in case of D1-Error)
7 min.
5 min.
C-fan and comp.
are linked.
2. Initial Defrosting
If D-sensor < 3.5C, defrosting mode starts from Pre-Cool at initial power input or
first plugin.
Pre-Cool
Heater
Defrosting
Pause
Fan Delay
-
2
4
-
=
=
=
Summary of Contents for FRS-2021
Page 3: ...1 EXTERNAL VIEWS 1 1 EXTERNAL SIZE FRS 2021 2 ...
Page 4: ...FRS 2041 3 ...
Page 39: ...CODE WSBS1 3 4 DIAGRAM 4 1 WIRING DIAGRAM 38 ...
Page 40: ...4 2 CIRCUIT WIRING DIAGRAM Main PCB 39 ...
Page 41: ...Front PCB 40 ...
Page 42: ...4 3 AIR FLOW DIAGRAM 41 Freezer Compartment Refrigerator Compartment ...
Page 60: ...141 1 141 141 2 141 3 141 4 141 5 141 6 129 2 129 1 155 1 155 3 155 2 155 FRS 2041 59 ...
Page 68: ...Daewoo Electronics Corp 67 ...