CONTENTS
REMARKS
6. Control point of each mode
Temp
MODE
ON point
OFF point
Low
Mid
High
STEP DIFF
STEP DIFF
ON/OFF
DIFF
(0.35 deg)
0.65
2.65
2.3
-1.35
-1.7
Weak refrigeration point
(Off point+7C)
7.3
1.65
-0.35
-0.7
1.3
(Low-Mid)
(Mid-High)
0.3
6.3
5.3
8.3
9.3
C
7. Super refrigeration proceeds for 40 minutes.
* Example of temperature change
(Refrigerator ; Low (normal) -> Super refrigeration )
1) R-fan and comp. are ON until R-sensor reaches to over-refrigeration OFF
point (-7C).
2) After reaching to the point, it goes on with “HIGH” mode until the end of
Super refrigeration.
It returns to normal after Quick refrigeration of 40 minutes.