62
Start
Level the refrigerator by
adjusting wheels.
☞
Refer to User’s Guide
and SVC Manual.
Y
N
Set it right.
Y
N
Change the Rubber absorber.
Y
N
Attach a restrainer on the comp.
head to reduce vibration and
high frequency noise.
Y
N
Change the compressor.
Remarks
●
Compressor sound is somewhat normal because it works like a heart to circulate the refrigerant in
the pipes during the refrigerator operation.
●
Rattling or metallic touch sound of motor, piston of comp. can be heard when it starts or stops.
8-4. Operation Noise of Refrigerator
8-4-1. Comp. operation Noise
Refrigerator is leveled ?
Front cover or door gasket
is assembled wrong ?
Rubber absorber comp
is distorted or aged ?
Sound from Comp itself
or Vibration ?
Summary of Contents for FRN-U20IE series
Page 4: ...3 2 1 External Size 2 EXTERNAL VIEWS FRS N U20IE...
Page 5: ...4 FRS N U20DE EE...
Page 6: ...5 FRS N U20FE GE...
Page 9: ...8 Freezer Compartment Refrigerator Compartment 2 3 Cold Air Circulation...
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 82: ...81 10 5 Dispenser Water Flow...