25
1. How to start
1) Under “LOCK” mode, press “SUPER FREEZER” button 5 times while pressing
“FREEZER SET” button at the same time.
2) The front CLED displays as the right diagram shows
( [Ex.] Time Display of 0003 signifies 3 minutes of power on time.)
3) Press “FREEZER SET” button and the following value is displayed successively.
①
Time
②
F-Sensor temperature
③
D-Sensor temperature
④
R-Sensor temperature
⑤
RT-Sensor temperature
⑥
P Factor display (Refer to water supply mode of automatic icemaker)
⑦
Filter remaining time until change (First check ; 4,320Hr)
Refer to Filter Information Reset of CLED of front control panel.
4) Error is displayed only if there is any ; it is skipped if no error.
2. How to stop
1) Push “LOCK” button 1 time.
2) It stops automatically in 4 minutes from the start.
3. All the error Codes are reset if they turn to be normal.
4. Error code
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
Temperature Control Buttons
88 Display CLED
Display forced defrost mode for A/S
D2
Display Full Down mode
Co
Return after defrosting : abnormal or defective
F3
Cycle : abnormal or defective
C1
Full ice switch : error
Eu
Drop the ice while Et
EA
Micro switch : error
ES
Water supply : error
Eg
Horizontal switch : error
Et
Flow sensor : defective
EF
I-sensor : disconnection (
“
Lo
”
), short (
“
Hi
”
)
EI
Home bar Door Switch : defective
dH
F-Door Switch : defective
dF
R-Door Switch : defective
dr
D-sensor : disconnection (
“
Lo
”
), short (
“
Hi
”
)
d1
RT-sensor : disconnection (
“
Lo
”
), short (
“
Hi
”
)
rt
R-sensor : disconnection (
“
Lo
”
), short (
“
Hi
”
)
r1
F-sensor : disconnection (
“
Lo
”
), short (
“
Hi
”
)
F1
CONTENTS
ERROR CODE
4-9-3. Dispenser Model
Summary of Contents for FRN-U20IE series
Page 4: ...3 2 1 External Size 2 EXTERNAL VIEWS FRS N U20IE...
Page 5: ...4 FRS N U20DE EE...
Page 6: ...5 FRS N U20FE GE...
Page 9: ...8 Freezer Compartment Refrigerator Compartment 2 3 Cold Air Circulation...
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 82: ...81 10 5 Dispenser Water Flow...