43
NO
DISASSEMBLING PROCEDURE
NO
DISASSEMBLING PROCEDURE
1
4
2
5
3
6
▷
Remove 2 screws.
▷
Pull forward Bracket Geared Motor.
▷
Unscrew (4 points).
▷
Separate 6 pin housing of Bracket
Geared Motor from the top connector.
▷
Check Solenoid Valve and Geared Motor.
2) How to Check Hose Ice Maker Tube Assembly
SPEC.
CRITERION
▷
GOOD : 11.3
Ω
(
±
10%)
(10.8 ~ 12.7
Ω
)
▷
DEFECTIVE ;
Change the Geared Motor.
PARTS
HOW TO CHECK
▷
GOOD : 145
Ω
(
±
8%)
(133 ~ 156
Ω
)
▷
DEFECTIVE ;
Change the Cube Sol Valve.
▷
Check resistance value of
2 terminals with a Multi Tester.
▷
SPEC. NAME
:DAG-6502DEC
▷
VOLTAGE
:220/240V,50Hz
▷
SPEC. NAME
:Cube SN8
▷
VOLTAGE
:220/240V,50Hz
▷
Check resistance value of
2 terminals with a Multi Tester.
Geared Motor
Cube Sol Valve
7-2. Bracket Geared Motor Assembly
1) Disassembling Procedure
Unscrew (red 4 screws).
Unscrew (blue 4 screws).