7-3. Defrost Mode
●
Initial Defrost
INPUT
CONTROL OBJECT
●
Total COMP Work Time
●
COMP Working Rate
●
Total Door Open Time
●
RT
●
Defrost Mode
A.
In providing initial power or returning power failure,
if the temperature at the D sensor is under 3 5
°
C Defrost Mode starts (It proceeds from “PRE COOL” )
●
Flow Chart of
Defrost Start
Start
COMP time
≥
2hrs
NO
if the temperature at the D-sensor is under 3.5 C, Defrost Mode starts. (It proceeds from PRE-COOL .)
[
“PRE-COOL”
→
Heater on
→
Pause(10 min)
→
General operation
]
B.
Initial defrost mode starts after “Prevention of Compressor Restart”. (Refer to Function No. 5)
Total time
≥
60hrs
COMP time
≥
14hrs
COMP time
≥
2hrs
YES
YES
YES
NO
COMP time
≥
6hrs
COMP Rate
≥
80%
YES
N0
N0
N0
NO
Any error?
Total door open time
RT Temp
≥
40
°
C
YES
YES
YES
NO
N0
Total door open time
≥
3 min?
END
Defrosting start
NO
22