29
NO.
Control Control
Contents Remark
Function Objects
8 Forced COMP.
defrost F-fan
9 Prevent COMP.
COMP. F-fan
restarting C-fan
10 Error LED
display
1. Press the quick freezing button 5 times, when press time set
button and then forced defrost mode is started.
2. It starts for heater on step without Pre-cool step.
3. After 14 hours of forced defrosting operation, regular
defrosting starts.
(Ignore accumulated COMP. time during forced defrost)
1. Restart in 6 min. after COMP. off
1. Press the quick freezing button 5 times, when press both the
freezer temperature button and then each sensors’
temperature and error code is displayed for 8 min.
2. Pressing the time set button each time to change display
status.
(D-sensor
➝
R-sensor
➝
F-sensor
➝
Error code
➝
D-sensor)
3. Error code is displayed in the following sequence :
F1
➝
R1
➝
D1
➝
D0
➝
F3
➝
C1
➧
Error code is refered to self-diagnosis table.
4. If all errors are removed, error code is automatically reset.
5. Press the quick freezing button 5 times, when press both the
freeaer temperature button again, and then remove the error
display on LED.
FRESH
CLEAN
A M
F R Z .
TIME SET
QUICK
FREEZING
FREEZER TEMP. CONTROL
TIME ADJUSTER
ECONOMIC
FREEZING
N
FRESH
CLEAN
F R Z .
TIME SET
QUICK
FREEZING
FREEZER TEMP. CONTROL
TIME ADJUSTER
ECONOMIC
FREEZING
C