28
NO.
Control
Control
Contents
Remark
Function
Objects
6 Economic COMP.
F-fan
freezing
C-fan
LED
7
Defrost COMP.
mode
Heater
F-fan
C-fan
1. When the economic freezing button is pressed the LED lights
and the operation is started.
2. When press the quick freezing button in the economic freezing
mode, quick freezing is operated and returns to previous
temperature setting after completion.
3. Press the economic freezing button again to return to the
previous temperature setting.
4. Press the temperature adjust button( , ) when return to
previous temperature setting.
1. When 9 hours of accumulated time passed, the defrost starts
nuconditionally.
2. After minimum 6 hours of COMP. accumulated time, the
defrost will start, if the door is opened for more than 10 min.
3. Defrost mode time table is shown below.
Defrost start time
Pre-cool Heater on Pause
F-fan delay
COMP.
F-fan
Heater
C-fan
Time
(Initial defrost
6 min operation) 45 min
delay
(D-sensor failure)
40 min.
90 min. heater failure
7 min.
5 min.
Pre-cool step is The heater is off,
canceled, when
when D-sensor
D-sensor detects
detects above
-27.5
°
13 C
°
C
The priority order of The quick freezing Defrost mode is
the quick freezing mode is prior to prior to quick
mode in normal
Pre-cool step in freezing mode.
defrost mode.
defrost mode.
E F
FRESH
CLEAN
A M
F R Z .
TIME SET
QUICK
FREEZING
FREEZER TEMP. CONTROL
TIME ADJUSTER
ECONOMIC
FREEZING
9 hours
start defrost
6 hours
COMP.
accumulated
start time
Minimum
accumulated
time
The defrost will start,
if the door is opened
for more than 10 min.
Maximum
accumulated
time