16.
R-SENSOR
OFF POINT
ADJUSTING
OPTION
1) R-SENSOR OFF POINT can be adjusted by changing the input voltage of MICOM 26
pin.
2) The default of input voltage is 0V.
3) The changed OFF POINT is base OFF POINT + OFF POINT of input voltage.
4) The change of R-SENSOR OFF POINT depend on the input voltage of MICOM
MICOM
Input (V)
0
1.0
1.5
2.0
2.5
3.7
5.0
OFF
POINT
Variation
(ºC)
-0.5ºC
(DEF)
1.0ºC
down
2.0ºC
down
3.0ºC
down
1.0ºC
up
2.0ºC
up
3.0ºC
up
R26, R27
Resistan
ce
(kOhms)
Jumper
adoption
R27 : 40
R26 : 10
R27:23.3
R26:10
R27:15
R26:10
R27:10
R26:10
R27:3.5
R26:10
R27:10
R26:DEL
5) APPLICATION (MAIN PCB)
5.1- GENERAL: MICOM 26 port - 0V
5.2- DELETE J2 (CHANGING R OFF POINT 1DEG UP) : MICOM 26 port – 2.5V
LOW COOLING
OPTION
-
R-SENSOR OFF POINT ADJUSTMENT (1 DEG. DOWN)
-
J1 DELETION on LOW COOLING OPTION
Default resistance (31.4 Kohms) + 1.5 kohms = 32.9 Kohms
Operating on condition that R-SENSOR OFF point goes down 1ºC.
30