13. PCB CONTROL FUNCTION
13.1. ERF-XXXA
NO
FUNCTION
CONTENTS
1.
DISPLAY
1) VAC STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 1 TIME.
2) LOW STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 2 TIMES.
3) MID STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 3 TIMES.
4) HIGH STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 4 TIMES.
5) SUPER STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 5 TIMES.
6) ERROR LED DISPLAY (ON MAIN PCB)
?
FUNCTION DISPLAY
-
D1 ERROR : LED is off & on one time.
-
D2 ERROR : LED is off & on two times.
-
R1 ERROR : LED is on & off one time.
-
RT ERROR : LED is on & off two times.
-
EP ERROR : LED is on & off continually
-
DR ERROR : LED is on continually
-
FORCED DEFROST OF CONDITION: HIGH, LOW led Lamps are on
-
SHORT CIRCUIT OF CONDITION: SUPER, MIDDLE, VAC led Lamps are on
25
Summary of Contents for ERF-366A
Page 5: ...3 REAL VIEW 4...
Page 6: ...4 MACHINE ROOM VIEW 5 SCREW MACHINE...
Page 7: ...5 REFRIGERANT CYCLE 6 CAPILLARY TUBE...
Page 9: ...7 WIRING DIAGRAMS 8 7 1 ERF XX6A...
Page 10: ...7 2 ERF XX6N 9...
Page 11: ...8 PCB CIRCUIT DIAGRAMS 10 8 1 ERF XX6A...
Page 12: ...8 2 ERF XX6N 11...
Page 21: ...11 EXPLODE DRAWING 20...
Page 22: ...21...