NO CONTROL FUNCTION
CONTENTS
4 6
Pcb Control Functions
5.
Flow chart for
Determination of Defrost
6.
Defrost Mode
• General Defrost
1) START: By determination defrost condition
Accumulated running time of compressor
2) FLOW
H E AT E R
PA U S E ( 4 m i n . )
FAN DELAY(4 min.) CONTROL
1- HEATER
*On - When defrost condition mode is started.
*Off - When D-sensor is more than 10 deg.
If D1 ERROR is existance, Heater off by Time
* LIMIT TIME -80min (D2 ERROR) Case of Heater/Temp Fuse Open
If D1 ERROR is existance, Heater off by 30 min.
* HTR 30 SEC ON: To check DEFROST CURRENT (HEATER) in the
mass production line
2- PAUSE
* Time - 4 min.
* All devices are off
3- FAN DELAY
* Time - 4 min.
* Only compressor is on in the R-sensor on condition
start
10
11
12
13
14
15