background image

42

1) Specifications of Door Lock Switch 

6. Specifications, Operation, and Defect Inspection of Door Lock Switch

 

2) Defect Inspection of Door Lock Switch 

TYPE

Part Code

Model

Power

Locking Mechanism

DWM30-999PG 36169047230

DWM30-999PG

250V 16A

Bimetal operation on the PTC heat

Lock "On/Off" Time

Lock Off Type

Configuration 

1. Forced unlocking by Solenoid

1. Forced unlocking by Solenoid

Defects and 

Errors

Details 

Causes

Inspection of Defects and 

Errors

Resolution

Error 

Mode

A single 

"snapping" 

sound or 

two 

consecutive 

"snapping" 

sounds

A single "snapping" 

sound and two 

consecutive "snapping" 

sounds occur during 

the early operation and 

in the pause mode 

respectively: Applicable 

to "DF" type only

Normal noise

The noise is caused by the operation of 

solenoid to lock or unlock the "sliding cam" 

to lock or unlock the door.

-

Occurrence 

of "LE" 

Error

"LE" error occurs 

as the "snapping" 

sound continues to 

occur: Applicable to 

"DE" type only

1. "LE" error occurs 

without any 

"snapping" 

sounds in "DF" 

type.

2. "LE" error occurs 

in "DA" type.

Disconnected 

connector

Inspect the connection of 

connector with naked eyes

Insert 

connector

"LE"

Terminal 

disconnected 

from connector

See the disassembly and 

inspection manual for door 

lock switch below

Insert terminal: 

S/W No.4 or 5 

terminal

"LE"

Door poorly 

closed

-

Close the door 

completely

"LE"

Defect in door 

hook

-

Exchange the 

door

"LE"

Defect in catch 

cam

The abnormal "snapping" 

sound continues to occur.

Exchange the 

door switch

"LE"

Disconnected 

connector

Inspect the connection of 

connector with naked eyes

Insert 

connector

"LE"

Terminal 

disconnected 

from connector

See the disassembly and 

inspection manual for door 

lock switch below

Insert terminal: 

S/W No.2 or 3 

terminal

"LE"

Disconnected 

solenoid coil

See the picture below

Exchange the 

door switch

"LE"

Disconnected 

connector

Inspect the connection of 

connector with naked eyes

Insert 

connector

"LE"

Terminal 

disconnected 

from connector

See the disassembly and 

inspection manual for door 

lock switch below

Insert terminal: 

S/W No.2 or 3 

terminal

"LE"

DWM30-999PG(영_SM).indd   42

16. 8. 23.   오전 10:10

Summary of Contents for DWM30-999PG

Page 1: ...Service Manual DWM30 999PG 2016 08 Wall Mounted Front Load Washer MINI Wall Mounted Front Load Washer MINI DWM30 999PG _SM indd 1 16 8 23 10 10...

Page 2: ...is Wall Mounted Front Load Washer MINI 2 2 Specifications 4 3 Assembly Part List 5 4 PCB Functions 13 5 Wiring Diagram 27 6 Part List and Major Specifications 28 7 Installation 45 DWM30 999PG _SM indd...

Page 3: ...ons to ensure silent washing Containers for detergent and softener are discretely designed to prevent mixture The spoon shaped design enables you to apply the proper amount of detergent conveniently S...

Page 4: ...ute Wash As the Normal cycle takes only 29 minutes it speeds up the laundry process and reduces water and power consumption by 64 compared to regular front load washers 3 Baby Clothes Cleaning DWM30 9...

Page 5: ...s Dimension 550mm x 600mm x 302mm W x H x D Weight 16 5KG Standard Volume 28L Power 220 240V Power Consumption Wash 100W DWM30 999PG ODW30 999G ODW30 999B Heating 1400W D CV701PC AW Max Load Wash 2 5K...

Page 6: ...5 3 Assembly Part List 1 TUB AS A13 A01 A02 A03 A04 A11 A09 A12 A22 A21 A23 A24 A25 A26 A29 A28 A27 A30 A31 A20 A19 A32 A18 A17 A07 A16 A10 A14 A15 A08 A06 A05 DWM30 999PG _SM indd 5 16 8 23 10 10...

Page 7: ...4 3615418450 D M300 1 4 POM 1 OPTION A22 Y DIVIDER 3612512900 D M300 ATWD0404 1 4 DMT 1 A23 HOSE INLET 3613270980 DFE04 LLDPE ID 4 OD 6 0 575 A24 VALVE INLET 3615401000 AC 220 240V 50 60HZ SV 11CWB 0...

Page 8: ...GASKETAS 3611204540 D M300 D1 4 1 B02 GASKET DOOR 3612328000 D M300 EPDM 1 B03 PACKING DETERGENT PRPKCA3R80 D M300 NBR 2 B04 COVER TUB 3618831700 D M300 FRPP 1 B05 SCREW TAPPING 7122502508 T2S TRS 5 2...

Page 9: ...300 PP 2 C03 HANDLE DETERGENT 3612613121 D M300 ABS SPRAY 2 C04 CAP SCREW 36109 0002311 ABS WH1404A MINI 1 5 6 C05 DECORATOR FILM 36167 0076500 PET WFWM122C0NN01BCCX DWM30 999PG MINI 1 5 PJT 1 C06 PCB...

Page 10: ...3610916500 POM 2 4 DOOR INNER 36116 0019500 TR PETG HT91 SK GRAY MASTER BATCH DWD M300 1 5 HOOK DOOR 3613102000 D M300 ZNDC 1 6 HOOK SPRING 36130 0001801 00 HOOK SPRING SUS304 D1 4 L36 6 D M300 1 7 PI...

Page 11: ...10 5 BODY AS E01 No PART NAME PART CODE DESCRIPTION Q TY REMARK E01 BODYAS BODYAS 36104 0001811 36104 0001811 1 BODY 36104 0001812 36104 0001812 DWM30 999PG _SM indd 10 16 8 23 10 10...

Page 12: ...75800 D M300 PVC L 3M CLAMP ID 10 OD 14 1 F06 HOSE INLET 3613270980 DFE04 LLDPE ID 4 OD 6 1 F07 CORD POWERAS 3611339670 DTIII 2P 05 250V16A H05VV F 3X1 5 3M EURO 1 See page 46 F08 ELBOW UNION 36125128...

Page 13: ...088170 PVC1MMH 3MID 4DUCKSUNGACRYLICFOAM NEWWHITE 1 3610088180 PVC1MMH 3MID 2DUCKSUNGACRYLICFOAM NEWWHITE 1 G05 CONNECTOR VALVE INLET 36162 0001601 D M300 MIDDLE ID 23 OD 24 8 OPTION 1 METALVALVE 3616...

Page 14: ...n Spin Drain 1min Main Spin 3min Unlocking 1min TOTAL 29min 32min 31min 90min 5min 15min 50min 80min 365min NOTE 1 The water temperature is set at 90 C for the steam wash of baby clothes 2 The speed f...

Page 15: ...in Unlocking 1min TOTAL 29min 32min 31min 90min 5min 15min 50min 80min 365min NOTE 1 The water temperature is set at 90 C for the steam wash of baby clothes 2 The speed for the main and middle spin cy...

Page 16: ...NSIVE INTENSIVE 40 INTENSIVE 60 Regular Normal Delicate Tub clean SPIN QUICK 15 INTENSIVE 3 Add Rinse Up to 5 cycles are addable for all programs except for Quick 15 Up to 8 additionalcycles are avail...

Page 17: ...esupply of Water 1 The water level is measured every two minutes after the initial water supply to add water if the level is lower than the pre determined level 2 The motor stops running during the re...

Page 18: ...flow level during the Baby Care program the heating cycle is skipped The E3 error is displayed on the third occurrence of overflow detection and the wash cycle is suspended However the water continues...

Page 19: ...program 3 Water Supply 1 Only cold water is supplied to the rinse cycle 2 Fabric softener is added to the final rinse cycle 4 Resupply of Water 1 The water level is measured a minute after the rinse...

Page 20: ...5 WASH 3 Water level for INTENSIVE40 or INTENSIVE60 program 6 WASH 4 Water level for Delicate program 7 WASH 5 Water level for QUICK15 program s MAIN WASH 8 LOCK OFF Water level to unlock door Water l...

Page 21: ...cked when the water is measured at 61 C or hotter or the water level is above the safety level after the Power button is turned on 5 The door is unlocked promptly after the cycle is complete 6 The doo...

Page 22: ...ay the durability number rn number 3 Number of hall sensor errors b1 number 4 Number of IPM fault errors b2 number 5 Number of motor overload errors b3 number 6 Number of errors in motor arrangement b...

Page 23: ...ge 1 Conditions 1 The preset water level is not reached within 10 minutes after the water starts being drained 2 Overload situations caused by failures in drainage take place 18 times during the final...

Page 24: ...s to be drained 2 If the water level is first measured to be above the overflow level during the Baby Care program the heating cycle is skipped The E3 error is displayed on the third occurrence of ove...

Page 25: ...pears 3 b3 Error Motor overload error 4 b4 Error Failure in motor arrangement 5 b5 Error Failure in tracking the motor speed 6 b6 Error Error in DC LINK overvoltage 7 b7 Error Error in DC LINK low vol...

Page 26: ...Available for premium model only 1 The water temperature is 45 C or higher in the Delicate program The error occurs during operation only when the tub contains water 2 If the Power button is turned o...

Page 27: ...BLACK 4PIN 1 Vdd 2 GND 3 LEVEL SENSOR 4 W TEMP WF10 WHITE 4PIN 1 Vdd 2 GND 3 Ha 4 Hb WF7 WHITE 3PIN 1 W 2 V 3 U WF6 WHITE 2PIN HEATER OPTION 1 HEATER 2 HEATER WF5 WHITE 3PIN 1 POWER RELAY 2 P CORD 3...

Page 28: ...27 5 Wiring Diagram DWM30 999PG DWM30 999PG _SM indd 27 16 8 23 10 10...

Page 29: ...EMI FILTER RDFC 2720 MINI DRUM 250V 12A BRAKET DP 10 MICRO SWITCH MS 11D MO 11 X CAPACITOR 275 V M PCB CMI CM15 PCX2 335M 0 1 PILK 12 VARISTOR 560 V SVC561 14 Samwha 13 RELAY 250V 10 A RY8 GA 1A 12L G...

Page 30: ...PC 2 5 0 mH L 1 680 k R 2 0 47 X cap 2 1000pF Y cap MORSE DC 30 V 3 A AC 250 V 2 A M 0 1 PILKOR Samwha Capacitor GOLDEN GOLDEN TYCO SANYOU SANYOU GOLDEN TYCO SANYOU KODENSHI Namseong Electric 1st d c...

Page 31: ...energy from stator into mechanical energy It consists of the shaft and pulley to transmit the mechanical energy to outside Belt is fixed on the pulley to enable set rotation 2 STATOR The stator has a...

Page 32: ...n the opposite sequence to disassembly Motor s Functional Mechanism The device transforms electric energy into mechanical energy The motor contains a costly auxiliary driving gear is controlled by sem...

Page 33: ...ation Location of Cam Description The bellows are completely closed the location of cam is set at 0 degree and the connection is off The wash cycle does not start yet After the power supply is connect...

Page 34: ...f signals continue to be transmitted to the drain motor until the internal switch is turned on If the internal switch is turned on signals are sent to the drain motor for about 3 6 seconds which is su...

Page 35: ...the motor causes poor operation Assembly Re assemble the parts in the opposite sequence to disassembly STOPPER BASE MOTOR Drain Motor bellows Assembly 4 In the event of OE after remdy follow the belo...

Page 36: ...on 2 0mm or more 1 Specification 2 Operation If the power supply is connected to the water inlet valve the rod valve is drawn by the coil s magnetic field to open the diaphragm hall and push up the di...

Page 37: ...gs and blockages in pressure hoses Exchange the defective part E2 Defective valve Check the malfunctions in valve Exchangetheinletvalve Others Check any leaks from the sides of inlet valve Check any l...

Page 38: ...essed separate the inlet hose With the snap fit on outlet gray pressed separate the inlet hose 4 Unscrew a bolt Notes 1 Connect the inlet hose properly to the inlet red and outlet gray 2 Fasten the sc...

Page 39: ...designed to be cut off about a minute after overheating to prevent such problems The heater temperature is set at around 270 C The water heater must be used in water Water Heater Water Temperature Se...

Page 40: ...ached Water Resistance Table Exchange the temperature sensor H2 or H4 Exchange of Heater Exchange of Water Heater Disassembly 1 Remove 4 body fixing screws 2 Remove the detergent and softener containe...

Page 41: ...mit a square wave to display the oscillation cycle in a frequency format The frequency signals predetermined in the set play switching functions to control the head pressure in the tub After the wash...

Page 42: ...immeasurable Defects and Errors Details Causes Inspection of Defects and Errors Resolution PCB Error Mode Incessant water supply Water continues to be supplied although the inlet valve is functioning...

Page 43: ...LE error occurs without any snapping sounds in DF type 2 LE error occurs in DA type Disconnected connector Inspect the connection of connector with naked eyes Insert connector LE Terminal disconnecte...

Page 44: ...Error Mode Non openable Door Power cutoff or forced shutdown during operation After the power cutoff or forced shutdown during operation PCB MICOM is not able to open the door At least 5 minutes must...

Page 45: ...3X1 5SQ 250V 15A LONGWELLAUSTRALIA 3 EU 3611339660 3611339680 3611339670 3611339690 HONGCHANG DTIII 2P 05 250V 16A H05VV F 3X1 5 EURO 4 Chile 3611342840 3611342860 3611342850 3611342870 HONGCHANG DTI...

Page 46: ...nd multiple grounding wires in a single place 8 Connect the power cord Insert the inlet hose until the elbow makes a snapping sound Connect the clamp inside the synchronous motor after fixing the drai...

Page 47: ...l the inlet hose Underground water pipe obsolete pipe 1 Install union connector 2 Install filter inlet 3 Branch off the inlet hose 13 4 Install Water filter inlet option Connect the fixing nut 1EA aft...

Page 48: ...r service center as a special tool is required Contact the service center to relocate the installation Additional charge applies Relocation Exchange of Power Cord Organize inlet and drain hoses and po...

Page 49: ...DWM30 999PG _SM indd 48 16 8 23 10 10...

Page 50: ...ervice Manual 2016 08 23 M E M O 49p 186 x 259 16 08 23 1p 3p 4p 8p 9p 10p 11p 13p 14p 15p 16p 18p 19p 21p 27p 28p 40p 42p 44p _ 20p ABOUT THIS MANUAL VISION CREATIVE INC 6 4 NO NEED PRINT DWM30 999PG...

Reviews: