29
PCB ASS’Y
8. PRESENTATION OF THE P.C.B ASS’Y
MESSAGE CAUSE SOLUTION
Improper installation of drain hose.
The drain hose is blocked up by foreign
matter.
Drain motor is inferior.
The water tap is closed.
The water inlet filter clogged.
It passes over the 60 minutes, yet it doesn’t
come to assigned water level.
Wash loads get uneven during spin.
Poor installation of the unit.
The lid is opened.
The safety switch is inferior.
The load sensing is inferior. After the load
sensing operates about 7 seconds, the
message is displayed during 0.5 second
and water level is always fixed ‘high’.
The water level sensing is inferior.
Install drain hose properly.
Remove foreign matter from drain hose.
Change drain motor.
Open the water tap.
Clean the water inlet filter.
Check whether or not is comes to the
assigned water level.
Re-set wash loads evenly.
Proper installation.
Close the lid.
Change the safety switch.
Change the P.C.B. ASS’Y.
Check the water level sensor and the
contact part of the connector.
Concerning Error Message
Summary of Contents for DWF-200M(V)
Page 31: ...30 WIRING DIAGRAM APPENDIX Wiring Diagram non Pump Single Valve...
Page 32: ...31 WIRING DIAGRAM Non Pump Multi Valve...
Page 33: ...32 WIRING DIAGRAM Pump Single Valve...
Page 34: ...33 WIRING DIAGRAM Multi Valve...
Page 35: ...34 PARTS DIAGRAM Inverter Single Valve...
Page 36: ...35 PARTS DIAGRAM Parts Diagram...
Page 37: ...36 PARTS DIAGRAM...
Page 38: ...37 PARTS DIAGRAM...
Page 39: ...38 PARTS DIAGRAM...
Page 44: ...43 CIRCUIT DIAGRAM Circuit Diagram 201M...
Page 45: ...44 CIRCUIT DIAGRAM Circuit Diagram 200M 240M...
Page 46: ...45 CIRCUIT DIAGRAM Circuit Diagram 200MV 240MV...