9. PRESENTATION OF THE P.C.B ASS’Y
26
PCB ASS’Y
MESSAGE CAUSE SOLUTION
Improper installation of drain hose.
The drain hose is blocked up by foreign
matter.
Drain motor is inferior.
The water tap is closed.
The water inlet filter clogged.
It passes over the 30 minutes, yet it doesn’t
come to assigned water level.
Wash loads get uneven during spin.
Poor installation of the unit.
The lid is opened.
The safety switch is inferior.
The load sensing is inferior. After the load
sensing operates about 20 seconds, the
message is displayed during 0.5 second
and water level is always fixed ‘high’.
The water level sensing is inferior.
Install drain hose properly.
Remove foreign matter from drain hose.
Change drain motor.
Open the water tap.
Clean the water inlet filter.
Check whether or not is comes to the
assigned water level.
Re-set wash loads evenly.
Proper installation.
Close the lid.
Change the safety switch.
Change the P.C.B. ASS’Y.
Check the water level sensor and the
contact part of the connector.
Concerning Error Message
Summary of Contents for DWF-1089
Page 24: ...APPENDIX 27 WIRING DIAGRAM è Wiring Diagram Non Pump ...
Page 25: ...28 WIRING DIAGRAM è Non Pump Single Valve ...
Page 26: ...29 WIRING DIAGRAM è Pump ...
Page 27: ...30 WIRING DIAGRAM è Pump Single Valve ...
Page 28: ...31 PARTS DIAGRAM è Parts Diagram A10 ...
Page 29: ...32 PARTS DIAGRAM B20 B19 B18 B17 B15 B16 B21 B22 B23 B24 ...
Page 30: ...33 PARTS DIAGRAM C32 ...