Daewoo DWF-100B Service Manual Download Page 22

43

PARTS DIAGRAM

42

PARTS DIAGRAM

NO

PARTS CODE

PARTS NAME

EA

DESCRIPTION

REMARK

D07

3613218500

HOSE DRAIN I AS

1

PE-LD, EVA(L=219.5)

NON-PUMP

3613212100

HOSE DRAIN I

LDPE+EVA, L=184

PUMP

D08

3613208900

HOSE OVERFLOW

1

PE-LD L=280mm

NON-PUMP

D09

3615404000

VALVE DRAIN AS

1

5591D VE

NON-PUMP

D10

3610304500

BASE

1

SECEN 2.0Tx438x320

D11

3612718200

INNER EARTH WIRE

1

GREEN VSF(30/0.18)L=350

PHILIPPINES

3612713100

1

AWG18 16/0.26 GN/YW

STANDARD AREA

3966130200

AC 100V/50,60Hz, ST=18

#250CONN.

D12

450ED45100

MOTOR SYNCHRONOUS

1

AC 110-130V/60Hz, ST=18

#250CONN.

3966320300

AC 220V/60Hz, ST=18

#250CONN.

3966010200

AC 220-240V/50Hz, ST=18

#250CONN.

D13

3616007000

SPECIAL SCREW

20

SCM24H 6.5x24

D14

3616006900

SPECIAL SCREW

4

SCM24H 6.5x18

D15

3616500500

BELT V

1

M20.5

60Hz

3616500100

M21

50Hz

D16

3617305800

GEAR MECHANISM

1

GM-1094 ; KEVLAR

D17

7640802011

BOLT HEX

4

6B-1 8x20 SW MFZN

D18

3618301300

PLATE GEAR PROTECT

1

SBHG 1, 1.6T

D19

3611502800

CUSHION DOWN

2

P.O.M H=18mm

3964220420

AC 110V/60Hz, F34-1C

#250CONN.

3964820520

AC 127V/60Hz, F36-1C

#250CONN.

D20

3610019720

MOTOR CONDENSER

1

AC 220/60Hz, F3A-1C

#250CONN.

3964310530

AC 220V/50Hz, F32-2C

#250CONN.

3964610320

AC 240V/50Hz, F33-2C

#250CONN.

D21

3611502000

CUSHION UPPER

2

P.O.M

D22

3618401400

PULLEY MOTOR AS

1

ADC-12, DS=10, DP=48.5

60Hz

3618401420

ADC-12, DS=10, DP=53.0

50Hz

D23

7650804211

BOLT HEX

4

6B-1 8x42 S.P/W MFZN

D24

3618101400

NOZZLE BODY

1

PP

D25

3617801000

LINK BRAKE

1

P.O.M(F20)     

PUMP

NO

PARTS CODE

PARTS NAME

EA

DESCRIPTION

REMARK

B17

3610068700

HARNESS OUTER

1

50/0.18 GREEN ST710489-2

B18

3612502300

GUIDE DRAIN HOSE

1

PP(JI-360)

PUMP

B19

3618703760

TERMINAL PUMP

1

AC 250V/1A, #250CONN.

PUMP(AC220-240V)

3618703770

AC 125V/3.15A, #250CONN. PUMP(AC100-130V)

B20

3611405320

COVER PUMP

1

PP(B360F)

PUMP

3611405301

UL/CSA(466FWU,HFH-400)

PUMP

B21

7112501611

SCREW TAPPING

3

T1 TRS 5x16 MFZN

PUMP

3963220330

AC 110V/60Hz    

PUMP

B22

3963821530

MOTOR SHADED POLE

1

AC 120V/60Hz

PUMP

3963322730

AC 220V/60Hz

PUMP

3963513430

AC 220-240V/50Hz   

PUMP

B23

3611901530

FILTER AS     

1

DWF-5590DPNF, E-TYPE

PUMP

B24

-

FRAME TOP

-

-

DWF-7094,8094

C01

3616104000

BLANCER AS

1

DWF-1094

C02

3611900700

FILTER

2

NYLON

FILTER AS

C03

3611903000

FRAME FILTER

2

PP

: 3611903100

C04

3613008900

HOLDER

2

PP

C05

3616003700

SPECIAL SCREW

24

SUS 5.5x16

C06

3612504100

GUIDE FILTER AS

2

DWF-1094

C07

3618806900

TUB

1

SUS430D

C08

3618807000

TUB U

1

PP

C09

3616006200

SPECIAL NUT

1

ZDC2

C10

3616006500

SPECIAL WASHER

1

SUS304(WAVE)

C11

3617200600

FLANGE TUB

1

ADC 12, VE TYPE

C12

4505E83100

SPECIAL BOLT BASE

6

6.5x23

C13

3610908300

CAP PULSATOR

1

PP

C14

4505E3203A

SC. PULSATOR FIX AS

1

6x26.5 O-RING+SILOCK

C15

3619703500

PULSATOR AS

1

PINSERT 

D01

3614601700

RING SHOWER AS

1

DWF-1094(RING T+RING U)

D02

3618804300

TUB O 

1

PP(VE TYPE)

NON-PUMP

3618804310

PP(VE TYPE)

PUMP

D03

3619802600

SUSPENSION AS(B)

2

DWF-1094

SPRING:WHITE

D04

3619802500

SUSPENSION AS(F)

2

DWF-1094

SPRING:YELLOW

D05

4500D08180

CLAMP

1

SWC BUBB DIA.=8

D06

4500D08170

HOSE

1

ID=8.0, OD=12.0

L=360mm

✔ 

Caution :

In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. 
So, if you need the latest parts information, please refer to PPL (Parts Price List) in Service Information Center
(http://svc.dwe.co.kr)

✔ 

Caution :

In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. 
So, if you need the latest parts information, please refer to PPL (Parts Price List) in Service Information Center
(http://svc.dwe.co.kr)

Summary of Contents for DWF-100B

Page 1: ...L 4 4 WASHING PROCEDURE AND COURSE SELECTION FULL AUTOMATIC COURSE 6 RESERVED WASHING 7 PARTIAL SELECTION AMONG WASH RINSE OR SPIN 7 5 DIRECTIONS FOR INSTALLATION AND USE INSTALLATION OF THE UNDER BASE COVER 8 HOW TO INSTALL ON AN INCLINED PLACE 8 HOW TO CONNECT THE INLET HOSE 9 HOW TO CLEAN THE FILTER 10 6 FEATURE AND TECHNICAL EXPLANATION FEATURE OF THE WASHING MACHINE 11 WATER CURRENT TO ADJUST...

Page 2: ... TIME DISPLAY O 19 AUTO WATER SUPPLY O 20 NEW WATER FLOW WATER FLOW FOR ADJUST THE UNBALANCED LOAD 21 FUNCTION FOR BUBBLE O 22 AUTO RE FEED WATER O 23 AUTO POWER OFF O 50Hz 400W 60Hz 430W 50Hz 400W 60Hz 430W 50Hz 480W 60Hz 550W 42 5Kg GROSS 48Kg 43 5Kg GROSS 49Kg 610mm X 965mm X 655mm 44 5Kg GROSS 50Kg 45 5Kg GROSS 51Kg 610mm X 980mm X 655mm 49Kg GROSS 56Kg 50Kg GROSS 57Kg 630mm X 980mm X 670mm NO...

Page 3: ...p Press this switch to turn the power on or off After turning off the power wait for more then 3seconds and then turn it on again It can be used to adjust amount of water according to the size of the load to be washed As the button is pressed water level is selected by E SMALL SMALL LOW MEDI UM HIGH It can be used to choose water temperature to be supplied As the button is pressed it will be repea...

Page 4: ... e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e g g g g g g Full Automatic Course Reserved Washing Reservation can be made from 2 hours to 48ho...

Page 5: ... f3 g f N 1 7 J HfJ H f7 g7 h Hg f g Hf 7 f f g f g Lf N f gN h 1 fN L f3 L e 3 L 3 L 5 7 f7 g 5g h f J f g f 5 f f g f g 1g f g h f 1 fN 1 e N 1 N 1 J H 5 f 5g Hg 5h f 7 5 f g f 3 H f f g f g 5g f L f h3 Lf 3 f f3 e L 7 5 J H f Hf J f J Hh3 f H f g f N g f g f g g f 1 fJ hN 1f N Lf 3 LfN L 3 1 J H 7 f J f 7 5 f 7 hN f gJ 5g f J g f g f g3 1g Lf e O h g 1f N 1f 3 1 N 7 e f 7 f H f h 3 f g7 Hg f 7 ...

Page 6: ...Therefore after 30 seconds the operation is interrupted to check the water level and then the water is supplied again until the select ed water level is reached mark indicates the operation of the water currents to adjust the unbalanced load NOTES How To Clean The Filter 4Remove the dirt from the inlet filter with a brush 1Pull the power plug out before cleaning it 2Turn off the water supply to th...

Page 7: ...process the water below the pul sator vanes creates a water currents as shown in figure The water is then discharged from the upper part of the tub through the water channel About 40 L min water is circulated at the high water level standard wash load and standard water currents 12 EXPLANATION FUNCTIONAL PRINCIPLE 1 The micom can remember the time from the begining of drain to reset point when the...

Page 8: ...g washing HOW TO REPLACE LINT FILTER 1 Pull the filter frame upward 2 Turn the lint filter inside out and wash the lint off with water 3 Return the filter as it was and fix the filter frame to the slot When the START HOLD button is pressed the residual time min is displayed on the time indicator and it will be counted down according to process When operation is finished the TIME INDICATOR will lig...

Page 9: ...NECT THE POWER CORD FROM THE ELECTRIC OUTLET W Wa ar rn ni in ng g To assemble the gear mechanism ass y reverse the disassembly procedure NOTES Mounting bolt Gear mechanism ass y Mounting bolt PRINCIPLE OF INTAKE OUTLET OF THE AIR INTAKE ARMATURE moves up and BELLOWS inhales the air At the same time protector B is open and A is close OUTLET ARMATURE moves down and BELLOWS exhausts the air At the s...

Page 10: ...ic outlet NOTES Concerning Water Supply Lay the front of the washer on the floor Loosen the adjustment screw and four bolts mounting the drain motor Take out the wire of drain motor from the bracket Loosen the adjustment screw fastening the bracket and place the adjustment screw to the brake lever as shown in figure Tighten the adjustment screw completely Loosen the adjustment bolt and turn the ad...

Page 11: ...y continue after the water reaches to the HIGH level Is the air tube of water level switch kinked or deformed CAUSE SOLUTION Change the water inlet valve The water inlet valve is defective The triac of P C B is defective Change the P C B ASS Y Normal operation Change the air tube Air tube is defective Change the pressure switch Pressure switch is defec tive PROBLEM THE PUL SATOR DOES NOT ROTATE EV...

Page 12: ...fec tive P C B ASS Y is defective Pressure switch is defec tive P C B ASS Y is defective There is foreign matter between pulsator and tub V belt is defective NO YES YES YES YES NO NO YES YES Abnormal YES YES NO NO Is Fuse opended Concerning Operation PROBLEM THE WASHER DOES NOT SPIN CHECK POINT Is the lid open Does the door switch operate normally Does the safety switch operate normally Does the p...

Page 13: ...The lid is opened The safety switch is inferior The load sensing is inferior After the load sensing operates about 15 seconds the message is displayed during 0 5 second and water level is always fixed high The water level sensing is inferior Install drain hose properly Remove foreign matter from drain hose Change drain motor Open the water tap Clean the water inlet filter Check whether or not is c...

Page 14: ...27 WIRING DIAGRAM 26 WIRING DIAGRAM Dwf 7094 Pump Dwf 7094 Non Pump Single Valve ...

Page 15: ...29 WIRING DIAGRAM 28 WIRING DIAGRAM Dwf 8094 1094 non pump single valve Dwf 8094 1094 non pump ...

Page 16: ...31 PARTS DIAGRAM 30 WIRING DIAGRAM Parts Diagram Dwf 8094 1094 pump ...

Page 17: ...ed the latest parts information please refer to PPL Parts Price List in Service Information Center http svc dwe co kr Caution In this Service Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please refer to PPL Parts Price List in Service Information Center http svc dwe co kr ...

Page 18: ... A08 5EP1048020 TRANS POWER 1 T5 V1F AC 110 130V FUSE 5EP1048030 T5 V2 AC 220 240V 5EP1048040 T5 V2F AC 220 240V FUSE A09 3619003100 SWITCH SAFETY 1 DC 15V 10mA SF 040A 3619003110 DC 15V 10mA SF 040F A10 3614514840 PLATE T 1 ABS NO METAL A11 3610907800 CAP SOFTENER 1 PP A12 3618101700 NOZZLE DETERGENT 1 PP A13 3611114700 CASE DETERGENT 1 PP A14 3615107900 SPRING DOOR 1 SUS 304 D 1 8 A15 3611718200...

Page 19: ...ITE A22 3618914810 UNIT FUSE FILTER 1 AC 250V 5A FERRITE TUV 3618918410 AC 250V 8A FERRITE PRPSSWXZ00 DWF 8094G1 NON PUMP PRPSSWX200 DWF 8094CTE CNE CME SINGLE VALVE A23 PRPSSWX100 P C B ASS Y 1 DWF 8094PT PN PM PL PUMP PRPSSWWX00 DWF 7094G3 NON PUMP PRPSSWWZ00 DWF 7094CTE CNE CME SINGLE VALVE PRPSSWWY00 DWF 7094PT PN PM PL PUMP 3612726910 250V 315mA DWF 8094 SINGLE VALVE 3612726930 250V 600mA DWF...

Page 20: ... PUMP 3618802630 PP 7 KG PUMP D03 3619802900 SUSPENSION AS A 2 DWF 8094 SPRING WHITE 3619800410 DWF 7094 SPRING WHITE D04 3619802900 SUSPENSION AS B 2 DWF 8094 SPRING YELLOW 3619800510 DWF 7094 SPRING YELLOW D05 4500D08180 CLAMP 1 SWC BUBB DIA 8 D06 4500D08220 HOSE 1 ID 8 0 OD 12 0 L 620mm D07 3613218500 HOSE DRAIN I AS 1 PE LD EVA L 219 5 NON PUMP 3613212100 HOSE DRAIN I LDPE EVA L 184 PUMP D08 3...

Page 21: ...O METAL 3615405420 AC 100 50 60Hz A03 3615405430 VALVE INLET COLD 1 AC 110 130V 60Hz 3615405400 AC 220V 60Hz 3615405440 AC 220 240V 50Hz 3615405210 AC 100V 50 60Hz 0EA SINGLE VALVE A04 3615405220 VALVE INLET HOT 1 AC 110 130V 60Hz 0EA SINGLE VALVE 3615405200 AC 220V 60Hz 0EA SINGLE VALVE 3614505230 AC 220 240V 50Hz 0EA SINGLE VALVE A05 3612902400 HINGE DOOR 2 POLYACETAL A06 3618918600 BUBBLE PUMP ...

Page 22: ...NN PUMP AC220 240V 3618703770 AC 125V 3 15A 250CONN PUMP AC100 130V B20 3611405320 COVER PUMP 1 PP B360F PUMP 3611405301 UL CSA 466FWU HFH 400 PUMP B21 7112501611 SCREW TAPPING 3 T1 TRS 5x16 MFZN PUMP 3963220330 AC 110V 60Hz PUMP B22 3963821530 MOTOR SHADED POLE 1 AC 120V 60Hz PUMP 3963322730 AC 220V 60Hz PUMP 3963513430 AC 220 240V 50Hz PUMP B23 3611901530 FILTER AS 1 DWF 5590DPNF E TYPE PUMP B24...

Page 23: ...DWF 7094 Circuit Diagram 44 CIRCUIT DIAGRAM ...

Page 24: ...45 CIRCUIT DIAGRAM DWF 8094 Circuit Diagram ...

Page 25: ...46 CIRCUIT DIAGRAM DWF 1094 Circuit Diagram ...

Reviews: