Daewoo DWF-100B Service Manual Download Page 21

41

PARTS DIAGRAM

40

PARTS DIAGRAM

NO

PARTS CODE

PARTS NAME

EA

DESCRIPTION

REMARK

PRPSSWZE00

DWF-1094G1

NON-PUMP

A23

PRPSSWZJ00

P.C.B ASS’Y

1

DWF-1094CTE/CNE/CME

SINGLE VALVE

PRPSSW

ZT

00

DWF-10

0 B

MEX- P

UMP

3612726710

250V/315mA

SINGLE VALVE,

A24

3612726730

HARNESS AS

1

250V/600mA

NON-PUMP

3612726720

250V/315mA

PUMP

3612726740

250V/600mA

3611302900

3x0.75, 300x2, L=1800

CP-2PIN

A25

3611302800

POWER CORD AS

1

A VCTFK 2x0.75 2.3M

FLAT 2PIN

3611302600

F H05W 3x0.75 2.3M

ITALIAN 3PIN

3611303300

GTSA-3 3x0.75 GY

ARGENTINE

A26

4500D08180

CLAMP

1

SWC BUBB DIA.=8

A27

4500D08170

HOSE

1

ID=8, OD=12

L=290mm

B01

3611201000

CLAMP

1

HSW3, D2.6, MFZN, D36

NON-PUMP

3611202200

HSW-3

PUMP

B02

3613213500

HOSE DRAIN O AS

1

EVA L=950mm

NON-PUMP

3613217800

HOSE DRAIN O

PE-LD

PUMP

B03

3614514600

PLATE UPPER   

1

PP

B04

3611413600

COVER BACK

1

SPG 0.5T

B05

7002501211

SCREW MACHINE

8

T2S TRS  5x12 MFZN

B06

3615302200

SUPPORT TUB BL

1

SPG T1.4

B07

3615302300

SUPPORT TUB BR

1

SPG T1.4

B08

3615302400

SUPPORT TUB FL

1

SPG T1.4

B09

3615302500

SUPPORT TUB FR

1

SPG T1.4

3618920400

54.0µF+60µH, L=470

110V, #250CONN.

B10

3618920500

ASSY CONDENSER  

1

41.6µF+60µH, L=470

127V, #250CONN.

3618919900

13.5µF+60µH, L=470

220V, #250CONN.

3618920000

11.5µF+60µH, L=470

240V, #250CONN.

B11

3610808010

CABINET

1

PAINTING

B12

3612603300

HANDLE CABINET

2

PP

B13

3610310200

BASE U

1

PP

NON-PUMP

3610310210

PP

PUMP

B14

4509D10020

FOOT

2

BUTYL RUBBER

B15

3617702100

LEG ADJUST AS

2

DWF-1089W2

B16

3611403710

COVER UNDER

1

PP

“UP”

NO

PARTS CODE

PARTS NAME

EA

DESCRIPTION

REMARK

A01

3612300110

GASKET VALVE

2

PVC-S

1EA;SINGLE VALVE

A02

3614217610

PANEL B

1

ABS, NO-METAL

3615405420

AC 100/50,60Hz

A03

3615405430

VALVE INLET COLD

1

AC 110-130V/60Hz

3615405400

AC 220V/60Hz

3615405440

AC 220-240V/50Hz

3615405210

AC 100V/50,60Hz

0EA;SINGLE VALVE

A04

3615405220

VALVE INLET HOT 

1

AC 110-130V/60Hz

0EA;SINGLE VALVE

3615405200

AC 220V/60Hz

0EA;SINGLE VALVE

3614505230

AC 220-240V/50Hz

0EA;SINGLE VALVE

A05

3612902400

HINGE DOOR

2

POLYACETAL

A06

3618918600

BUBBLE PUMP ASS’Y

1

AC 100-130V/50,60Hz

HOSE : 830mm

3618919200

AC 220-240V/50,60Hz

HOSE : 830mm

A07

3614800960

SWITCH PRESSURE

1

CDN-D7 Ø50.5

5EP1048010

T5-V1 (AC 110-130V)

A08

5EP1048020

TRANS POWER

1

T5-V1F(AC 110-130V)

FUSE

5EP1048030

T5-V2 (AC 220-240V)

5EP1048040

T5-V2F(AC 220-240V)

FUSE

A09

3619008920

SWITCH SAFETY

1

DC 15V 10mA SF-040T

A10

3614514510

PLATE T

1

ABS, NO-METAL

A11

3610907800

CAP SOFTENER

1

PP

A12

3618101700

NOZZLE DETERGENT

1

PP

A13

3611114700

CASE DETERGENT

1

PP

A14

3615107400

SPRING 

1

SUS 304 D=2.0

A15

3611717510

DOOR B    

1

ABS, NO-METAL

A16

3611717410

DOOR F

1

ABS, NO-METAL

A17

3612603210

HANDLE DOOR

1

ABS, NO-METAL

A18

3611504100

CUSHION DOOR 

2

CR

A19

7112503011

SCREW TAPPING

2

T1 TRS 5x30 MFZN

A20

3610907900

CAP

2

NBR

A21

3614217510

PANEL F

1

ABS, NO-METAL

3618918400

AC 250V/4A, FERRITE

A22

3618914810

UNIT FUSE FILTER

1

AC 250V/5A, FERRITE

TUV

3618918410

AC 250V/8A, FERRITE

2. DWF-1094

✔ 

Caution :

In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. 
So, if you need the latest parts information, please refer to PPL (Parts Price List) in Service Information Center
(http://svc.dwe.co.kr)

✔ 

Caution :

In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list. 
So, if you need the latest parts information, please refer to PPL (Parts Price List) in Service Information Center
(http://svc.dwe.co.kr)

Summary of Contents for DWF-100B

Page 1: ...L 4 4 WASHING PROCEDURE AND COURSE SELECTION FULL AUTOMATIC COURSE 6 RESERVED WASHING 7 PARTIAL SELECTION AMONG WASH RINSE OR SPIN 7 5 DIRECTIONS FOR INSTALLATION AND USE INSTALLATION OF THE UNDER BASE COVER 8 HOW TO INSTALL ON AN INCLINED PLACE 8 HOW TO CONNECT THE INLET HOSE 9 HOW TO CLEAN THE FILTER 10 6 FEATURE AND TECHNICAL EXPLANATION FEATURE OF THE WASHING MACHINE 11 WATER CURRENT TO ADJUST...

Page 2: ... TIME DISPLAY O 19 AUTO WATER SUPPLY O 20 NEW WATER FLOW WATER FLOW FOR ADJUST THE UNBALANCED LOAD 21 FUNCTION FOR BUBBLE O 22 AUTO RE FEED WATER O 23 AUTO POWER OFF O 50Hz 400W 60Hz 430W 50Hz 400W 60Hz 430W 50Hz 480W 60Hz 550W 42 5Kg GROSS 48Kg 43 5Kg GROSS 49Kg 610mm X 965mm X 655mm 44 5Kg GROSS 50Kg 45 5Kg GROSS 51Kg 610mm X 980mm X 655mm 49Kg GROSS 56Kg 50Kg GROSS 57Kg 630mm X 980mm X 670mm NO...

Page 3: ...p Press this switch to turn the power on or off After turning off the power wait for more then 3seconds and then turn it on again It can be used to adjust amount of water according to the size of the load to be washed As the button is pressed water level is selected by E SMALL SMALL LOW MEDI UM HIGH It can be used to choose water temperature to be supplied As the button is pressed it will be repea...

Page 4: ... e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e g g g g g g Full Automatic Course Reserved Washing Reservation can be made from 2 hours to 48ho...

Page 5: ... f3 g f N 1 7 J HfJ H f7 g7 h Hg f g Hf 7 f f g f g Lf N f gN h 1 fN L f3 L e 3 L 3 L 5 7 f7 g 5g h f J f g f 5 f f g f g 1g f g h f 1 fN 1 e N 1 N 1 J H 5 f 5g Hg 5h f 7 5 f g f 3 H f f g f g 5g f L f h3 Lf 3 f f3 e L 7 5 J H f Hf J f J Hh3 f H f g f N g f g f g g f 1 fJ hN 1f N Lf 3 LfN L 3 1 J H 7 f J f 7 5 f 7 hN f gJ 5g f J g f g f g3 1g Lf e O h g 1f N 1f 3 1 N 7 e f 7 f H f h 3 f g7 Hg f 7 ...

Page 6: ...Therefore after 30 seconds the operation is interrupted to check the water level and then the water is supplied again until the select ed water level is reached mark indicates the operation of the water currents to adjust the unbalanced load NOTES How To Clean The Filter 4Remove the dirt from the inlet filter with a brush 1Pull the power plug out before cleaning it 2Turn off the water supply to th...

Page 7: ...process the water below the pul sator vanes creates a water currents as shown in figure The water is then discharged from the upper part of the tub through the water channel About 40 L min water is circulated at the high water level standard wash load and standard water currents 12 EXPLANATION FUNCTIONAL PRINCIPLE 1 The micom can remember the time from the begining of drain to reset point when the...

Page 8: ...g washing HOW TO REPLACE LINT FILTER 1 Pull the filter frame upward 2 Turn the lint filter inside out and wash the lint off with water 3 Return the filter as it was and fix the filter frame to the slot When the START HOLD button is pressed the residual time min is displayed on the time indicator and it will be counted down according to process When operation is finished the TIME INDICATOR will lig...

Page 9: ...NECT THE POWER CORD FROM THE ELECTRIC OUTLET W Wa ar rn ni in ng g To assemble the gear mechanism ass y reverse the disassembly procedure NOTES Mounting bolt Gear mechanism ass y Mounting bolt PRINCIPLE OF INTAKE OUTLET OF THE AIR INTAKE ARMATURE moves up and BELLOWS inhales the air At the same time protector B is open and A is close OUTLET ARMATURE moves down and BELLOWS exhausts the air At the s...

Page 10: ...ic outlet NOTES Concerning Water Supply Lay the front of the washer on the floor Loosen the adjustment screw and four bolts mounting the drain motor Take out the wire of drain motor from the bracket Loosen the adjustment screw fastening the bracket and place the adjustment screw to the brake lever as shown in figure Tighten the adjustment screw completely Loosen the adjustment bolt and turn the ad...

Page 11: ...y continue after the water reaches to the HIGH level Is the air tube of water level switch kinked or deformed CAUSE SOLUTION Change the water inlet valve The water inlet valve is defective The triac of P C B is defective Change the P C B ASS Y Normal operation Change the air tube Air tube is defective Change the pressure switch Pressure switch is defec tive PROBLEM THE PUL SATOR DOES NOT ROTATE EV...

Page 12: ...fec tive P C B ASS Y is defective Pressure switch is defec tive P C B ASS Y is defective There is foreign matter between pulsator and tub V belt is defective NO YES YES YES YES NO NO YES YES Abnormal YES YES NO NO Is Fuse opended Concerning Operation PROBLEM THE WASHER DOES NOT SPIN CHECK POINT Is the lid open Does the door switch operate normally Does the safety switch operate normally Does the p...

Page 13: ...The lid is opened The safety switch is inferior The load sensing is inferior After the load sensing operates about 15 seconds the message is displayed during 0 5 second and water level is always fixed high The water level sensing is inferior Install drain hose properly Remove foreign matter from drain hose Change drain motor Open the water tap Clean the water inlet filter Check whether or not is c...

Page 14: ...27 WIRING DIAGRAM 26 WIRING DIAGRAM Dwf 7094 Pump Dwf 7094 Non Pump Single Valve ...

Page 15: ...29 WIRING DIAGRAM 28 WIRING DIAGRAM Dwf 8094 1094 non pump single valve Dwf 8094 1094 non pump ...

Page 16: ...31 PARTS DIAGRAM 30 WIRING DIAGRAM Parts Diagram Dwf 8094 1094 pump ...

Page 17: ...ed the latest parts information please refer to PPL Parts Price List in Service Information Center http svc dwe co kr Caution In this Service Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please refer to PPL Parts Price List in Service Information Center http svc dwe co kr ...

Page 18: ... A08 5EP1048020 TRANS POWER 1 T5 V1F AC 110 130V FUSE 5EP1048030 T5 V2 AC 220 240V 5EP1048040 T5 V2F AC 220 240V FUSE A09 3619003100 SWITCH SAFETY 1 DC 15V 10mA SF 040A 3619003110 DC 15V 10mA SF 040F A10 3614514840 PLATE T 1 ABS NO METAL A11 3610907800 CAP SOFTENER 1 PP A12 3618101700 NOZZLE DETERGENT 1 PP A13 3611114700 CASE DETERGENT 1 PP A14 3615107900 SPRING DOOR 1 SUS 304 D 1 8 A15 3611718200...

Page 19: ...ITE A22 3618914810 UNIT FUSE FILTER 1 AC 250V 5A FERRITE TUV 3618918410 AC 250V 8A FERRITE PRPSSWXZ00 DWF 8094G1 NON PUMP PRPSSWX200 DWF 8094CTE CNE CME SINGLE VALVE A23 PRPSSWX100 P C B ASS Y 1 DWF 8094PT PN PM PL PUMP PRPSSWWX00 DWF 7094G3 NON PUMP PRPSSWWZ00 DWF 7094CTE CNE CME SINGLE VALVE PRPSSWWY00 DWF 7094PT PN PM PL PUMP 3612726910 250V 315mA DWF 8094 SINGLE VALVE 3612726930 250V 600mA DWF...

Page 20: ... PUMP 3618802630 PP 7 KG PUMP D03 3619802900 SUSPENSION AS A 2 DWF 8094 SPRING WHITE 3619800410 DWF 7094 SPRING WHITE D04 3619802900 SUSPENSION AS B 2 DWF 8094 SPRING YELLOW 3619800510 DWF 7094 SPRING YELLOW D05 4500D08180 CLAMP 1 SWC BUBB DIA 8 D06 4500D08220 HOSE 1 ID 8 0 OD 12 0 L 620mm D07 3613218500 HOSE DRAIN I AS 1 PE LD EVA L 219 5 NON PUMP 3613212100 HOSE DRAIN I LDPE EVA L 184 PUMP D08 3...

Page 21: ...O METAL 3615405420 AC 100 50 60Hz A03 3615405430 VALVE INLET COLD 1 AC 110 130V 60Hz 3615405400 AC 220V 60Hz 3615405440 AC 220 240V 50Hz 3615405210 AC 100V 50 60Hz 0EA SINGLE VALVE A04 3615405220 VALVE INLET HOT 1 AC 110 130V 60Hz 0EA SINGLE VALVE 3615405200 AC 220V 60Hz 0EA SINGLE VALVE 3614505230 AC 220 240V 50Hz 0EA SINGLE VALVE A05 3612902400 HINGE DOOR 2 POLYACETAL A06 3618918600 BUBBLE PUMP ...

Page 22: ...NN PUMP AC220 240V 3618703770 AC 125V 3 15A 250CONN PUMP AC100 130V B20 3611405320 COVER PUMP 1 PP B360F PUMP 3611405301 UL CSA 466FWU HFH 400 PUMP B21 7112501611 SCREW TAPPING 3 T1 TRS 5x16 MFZN PUMP 3963220330 AC 110V 60Hz PUMP B22 3963821530 MOTOR SHADED POLE 1 AC 120V 60Hz PUMP 3963322730 AC 220V 60Hz PUMP 3963513430 AC 220 240V 50Hz PUMP B23 3611901530 FILTER AS 1 DWF 5590DPNF E TYPE PUMP B24...

Page 23: ...DWF 7094 Circuit Diagram 44 CIRCUIT DIAGRAM ...

Page 24: ...45 CIRCUIT DIAGRAM DWF 8094 Circuit Diagram ...

Page 25: ...46 CIRCUIT DIAGRAM DWF 1094 Circuit Diagram ...

Reviews: