58
• Situation : PCB shows "H7".
cause)
☛
Dry heater is cut-off.
☛
Fuse temp. is cut-off.
repaire method)
☛
replace the Dry heater.
☛
replace the Fuse temp.
checking point
part name
checking results
repaire method
HEATER
SENSOR TEMP.
FUSE TEMP.
dry Heater is short or cut-off.
Thermistor is short or cut-off.
FUSE TEMPERATURE is cut-off.
replace the
dry Heater.
replace the
Thermistor.
replace the
FUSE
TEMPERATURE.
THERMISTOR
HEATER DRY
FUSE
TEMPERATURE